High End Systems 2.0.0-EN Manuale Utente

Pagina di 466
Figure 31.1. The Launched Processes window
3.
Check the network settings. The DMX Processor and console both need to be
on the same subnet.
4.
Check the port number setting. The DMX Processor and console both need
to have the same Port Number. See HogNet Network (p.64).
5.
Check the software. The DMX Processor and console both need to be running
the same version of the software; see Updating the DMX Processor Software
(p.392)
.
31.4
Playback controls don't behave as expected
Check that the playback controls haven't been mapped to different functions
to their normal ones. See Configuring Playback Controls (p.283).
31.5
The Front Panel Reboots Unexpectedly
Care should be taken when transmitting a personal radio while in close proximity to a console
front panel. Always keep radio transmitting devices at least eight inches from the console surface.
In the event of a radio transmitting within close proximity of the console, the front panel firmware
may reboot causing a temporary loss of control of the keys and hardware for approximately 20
seconds. During this time the desk lights may dim as well. After 20 seconds the front panel will
reboot and normal functionality will be restored. If the problems persist, move the radio transmit-
ting device further from the console.
High End Systems
420
Section 31: Troubleshooting