Cisco Cisco D9804 Multiple Transport Receiver Guida All'Installazione

Pagina di 220
 
 
 
Connecting the Unit 
 
78-4042990-01 Rev B 
 
For further information, see the specific product manuals in question. When 
connecting the power source to the D9804 MTR it takes less than a minute for the 
unit to initialize. The front panel display shows the startup screen. 
 
Maintenance of EMC Compliance 
Double-shielded (braid/foil or braid/braid) cables should be used for all ASI I/O 
and RF inputs. Single-shield cables are acceptable for all other inputs and outputs. 
For terminal block (Alarms) I/O, no shielding is required. 
Control/Connector 
Type   
Description 
RF Inputs 
Each input accepts an LNB signal input. RF1, RF2 and 
RF3 can provide remote LNB power for use when no 
external LNB power source is available. 
ASI Input 
BNC 
 
Asynchronous Serial Interface Input. 
ASI Outputs 
BNC 
Six sets of two duplicate Asynchronous Serial 
Interface Outputs. Although not labeled on the rear 
panel, the top row is designated 1a to 6a, and the 
bottom row is designated 1b to 6b. 
Ethernet 
 
RJ-45 
Ethernet IP data control and monitoring. 
RS-232 Control 
DB-9 
Telemetry data output: 7 bits, even parity, 1 stop bit, 
9600 bps. These outputs are user-configurable. 
Alarms  
 
 
7xNO/NC contacts triggered by programmable alarm 
conditions. 
Ground  
Screw 
Grounding point for the receiver.