Read the plot
Scan axis and paper axis printhead registration
The colored crosses on the left side of the plot should show the lines well aligned with each other.
The central die of the light cyan printhead is used as a reference to which the rest of the pens are 
compared. The substrate does not move while the pattern is printed.
Scan axis angular check
The vertical lines to left of center should be straight, without kinks.
The small arrow points to the place where lines printed in subsequent passes meet. The registration 
should be checked at that point for the KC, lm and MY printheads (MY is not shown). Please note 
that media advances between the printing of the upper and lower parts of the plot.
The Angular alignment check is heavily dependant on perturbations of the substrate. Occasionally, 
events such as IPS Substrate Load or any other that repeatedly moves substrate forward and 
backward may distortion the Angular check. In this case, move media forward for 20 inches and 
repeat the Printheads Alignment Diagnostic plot.
Problems in the Angular alignment lead to M-Y to C-K pen-to-pen mis-registration. This is because of 
the staggered disposition of the Printheads. For example, if an M line has an incorrect Angular 
alignment it will move towards Media Output with a certain skew, and a subsequent K line in the 
same position will show misregistration.
The Angular alignment can slightly change when media type or size varies, or when media has 
recently been loaded into the printer.
Pattern printed before media advance
Pattern printed after media advance