Caution!
Protect an optical fiber with the winding tube when routing the optical fiber inside the
cabinet. Protect an optical fiber with the corrugated pipe when routing the optical fiber
outside the cabinet.
– End of Steps –
5.4 Installing the Interconnected Cable Between BBU
and RSU
Prerequisites
l
The ZXSDR RSU82C cabinet has already been installed.
l
The BBU module and RSU module have already been installed.
Context
ZXSDR RSU82CIn the system, optical fibers or SFP cables can be used to connect BBU
and RSU. During the stacked installation of the ZXSDR RSU82C, a 2 m SFP high-speed
cable is recommended for interconnecting BBU and RSU.
shows an SFP
cable.
Figure 5-12 High-Speed Cable
5-12
SJ-20101019140047-001(R1.2)|08/08/2011
ZTE Proprietary and Confidential