Maximum Link Attempts
The Maximum Link Attempts setting controls the number of times the scan-
ner tries to form a connection with a base unit or PC.  During the connec-
tion setup process, the scanner transmits in order to search for and 
connect to a base unit.  In order to prevent continuous transmissions that 
could interfere with other users of the ISM band, the number of attempts to 
connect is limited by this setting.  After the maximum number of attempts is 
reached, the scanner will not attempt to reconnect to the base unit.  Press-
ing the trigger or placing the scanner in the cradle resets the attempt count 
and the scanner will again try to link to the base unit.  When set to zero, the 
scanner will try to link until the Power Time-Out Timer setting (see 
) expires.  
Scan the Maximum Link Attempts bar code, then scan the number of 
attempts for the setting (from 0-100) from the inside back cover.  Scan Save 
to save the setting.  
Default = 0.
Relink Time-Out
Relink Time-Out controls the idle time between re-link attempts.  An 
attempt to link a scanner to a base unit typically lasts up to 5 seconds.  This 
is the time when the scanner is actually attempting to contact base unit.  
Relink Time-Out controls the amount of time, in seconds, that elapses 
between the end of one connection attempt and the start of the next.
Note: The length of time for an attempt depends on the number of scanners 
connected to a base unit.  An extra 7 seconds may be required when 
a connection is successful.
Scanner reset due 
to firmware 
upgrade
Re-link occurs automatically.
Scanner reset due 
to battery change
Re-link occurs automatically.
Scanner placed in 
different base unit
Re-link to new base occurs automatically.
Event
Auto Reconnect On
Auto Reconnect Off
Maximum Link Attempts