Honeywell International Inc. 7850LPE Manuale Utente

Pagina di 116
9 - 4
Using the Battery Analyzer 
The battery analyzer helps you monitor the charge capacity of Li-ion batteries over time. The battery analyzer is the fourth slot 
of the ChargeBase, labeled the CHARGE/ANALYZE. 
Analyze Button
The Analyze cycle is initiated when a battery is placed in the Charge/Analyze slot and the ANALYZE button is pressed. In an 
Analyze cycle, batteries are completely discharged, then recharged to capacity. The battery is completely reset and re-calibrated.  
The amount of time required for a battery to complete the Analyze cycle depends on initial state of the battery’s charge. Minimum 
time is 8 hours, maximum time is 12 hours.
Battery Capacity Indicator LEDs
These LEDs display the charge capacity of the battery at the end of the Analyze cycle. Battery capacity is displayed as a 
percentage of measured capacity/rated capacity where each LED equates to 10% battery capacity. The readout tells you the 
maximum charge level the battery can hold.
Status LED
The Charge/Analyze slot also contains a standard status LED in the upper, left corner of the slot. When this slot is used for regular 
charging, this LED operates in the usual manner; see 
When this slot is being used to analyze a battery, the status LED functions as follows:
To Analyze a Battery
1. Insert the battery into the Charge/Analyze slot (the fourth).
2. Press the ANALYZE button. The Status LED flashes orange to indicate that the analyzing cycle has begun.
3. Upon completion of the Analyze cycle, the Status LED lights solid green, and the Battery Capacity Indicator LEDs display 
the battery’s capacity.
The Dolphin QuadCharger is accumulating battery pack information during the entire Analyze cycle. Do NOT remove the battery 
until the cycle has been completed. 
Color
Description
Solid Green
The battery has completed the Analyze cycle. 
Flashing Orange
The battery is currently being analyzed. 
Solid Red
The QuadCharger encountered an error during the Analyze cycle.
!