Step Action 
Display 
Enter [4] (Loop Functions). Enter the loop number (1-4).  
Note: The FA270RF is shipped with the loop functions pre-
programmed. Perform steps 6 through 10 only if it is necessary 
to change any of the loop functions. 
Loop 1 
Close the FA270RF On-Board Relay for two seconds. 
Loop 2 
1 (Disarm) 
Loop 3 
2 (Arm Away) 
Loop 4 
3 (Arm Stay) 
See the Wireless Key Function Chart below for the choices. 
Wireless Key Function Chart 
 
Function Entry 
 
 
Disarming 1 
 
 
Arming Away 
 
 
Arming Stay 
 
 
Arming Maximum (Away Instant) 
 
 
Arming Instant 
 
 
Panic Alarm   
Produces type of alarm [* & #] 
programmed in control panel.
 
# + 99   
 
 
Manually Start a Relay Action 
# + 7   
(FA142C)  
# + 7 + n  (FA148C, FA148CP, 
 FA162C, 
FA168CP) 
 
 
Manually Stop a Relay Action 
# + 8   
(FA142C)  
# + 8 + n  (FA148C, FA148CP, 
 FA162C, 
FA168CP) 
 
 
 
 
 
 
Activate Relay as Programmed in 
Control 
# +71   
(FA1220C, FA1220CV, 
 FA1340C, 
FA1600CA) 
 
 
Activate Relay as Programmed in 
Control 
# + 72    (FA1220C, FA1220CV, 
 FA1340C)
 
 
 
Activate Access Control Relay for 
Partition 
0   
(FA1220C, FA1220CV, 
 FA1340C) 
 
n = Device Number programmed in FA162C to be controlled 
Press the [
✱] key.
 
Flashes "Ln." 
Once the loop number is 
entered, alternately flashes 
"L" with the loop number 
and the present function. 
 
Default Loop Functions 
 
5 8 0 4
Loop 3
Arm AWAY
Loop 1
Close on-board relay 
for 2 seconds
Loop 2
Disarm
Loop 4
Arm STAY
 
5 8 0 4 B D / 5 8 0 4 B DV
Loop 3
Arm AWAY
Loop 1
Close on-board relay 
for 2 seconds
Loop 2
Disarm
SET 
HOUSE 
CODE
••
• •
•••
Loop 4
Arm STAY
 
 
NOTE: If the loop is 
defaulted with a function 
(e.g., Arm, Disarm) and also 
is assigned to activate the 
on-board relay, the system 
performs BOTH functions. 
Repeat step 6 for the rest of the loops of the wireless key.  
 
To program a button on the wireless key to control the on-board 
relay, enter [5] (On-Board Relay Assignment).  
Flashes "o-." 
Enter the loop number of the wireless key (1-4). Enter the relay 
action (0 = no action; 1 = relay off; 2 = relay on; 3 = relay toggles on 
and off; 4 = relay closes for 2 seconds).  
Note: The relay action must be "0" for UL installations. 
Press the [
✱] key. 
Flashes “o” and the loop 
number. 
Once the action is entered, 
displays “o” and alternately 
flashes the loop number and 
the relay action. 
10 
Repeat step 9 for the rest of the loops. 
 
11 
When all loops have been programmed for the wireless key, press the 
[
✱] key. 
Flashes “d” followed by the 
device number. 
12 
The FA270RF automatically displays the next available device 
number (one that does not have a serial number). 
If you want to program additional wireless keys, repeat steps 3 
through 10. Otherwise, press the [#] key.  This takes you back to the 
main display, which alternately flashes “oo” and “- -.” 
 
13 
Enter [0] (High-Security Mode). To put the system into High-Security 
mode, enter [1]. Enter [0] to disable  
En 
14 Press 
[
✱] to exit the FA270RF Program mode. 
 
Note:
 
Upon exiting the Program mode, the FA270RF alternately flashes "Ad," the 2-digit keypad address, and the 2-digit 
receiver address.  If either of these is incorrect, repeat steps 1 through 3 in the Programming for an Installation 
Without Local Wireless Keys