Kwikbit Inc. PTP55DP Manuale Utente
M4-2000
User Guide
Kwikbit M4-2000 User Guide
Confidential & Proprietary
- 35 -
3. Without moving the Primary unit, adjust the azimuth and elevation angle of the Secondary
unit for maximum link quality. Link quality is to be monitored via a unit’s Link Setup Meter
as described in the previous section
as described in the previous section
4. Without moving the Secondary unit adjust the azimuth and elevation angle of the Primary
unit for maximum link score
5. Repeat steps 3 and 4 to fine tune the alignment. Note: If the installation is in a complete
NLoS situation, repeat the alignment process by pointing the Primary antenna in different
directions for maximum CINR reading on the Secondary unit.
6. Once the alignment process is complete and the best signal quality is achieved, secure the
Primary and Secondary units by tightening the mounting screws
5.2 System configuration
After the Primary and the Secondary units are preconfigured and installed, connect to both units
from a Management PC on the Management network. The Management PC needs to have an IP
from a Management PC on the Management network. The Management PC needs to have an IP
address on the Management network to be able to communicate through the pre-configured
Management IP gateway. To verify connectivity from a terminal window, issue the ping command
as follows:
as follows:
➢
ping [M4-2000 unit’s assigned IP address]
Once connectivity is established, open a browser window on the Management PC and enter the
target unit’s IP address in the URL field. On the Login page enter the pre-configured Name and
Password. The Main management page will open, which provides a summary of unit status, state
Password. The Main management page will open, which provides a summary of unit status, state
and configuration information. To further configure the unit, follow the configuration pages from
the main menu on the left side of the Main page. Please see Section 6 for configuration options.
Following configuration of the Primary unit, connect to the Secondary (remote) unit by entering its
IP address in the URL address field. Note that in order to be able to connect to the remote unit
the main menu on the left side of the Main page. Please see Section 6 for configuration options.
Following configuration of the Primary unit, connect to the Secondary (remote) unit by entering its
IP address in the URL address field. Note that in order to be able to connect to the remote unit
management over the airlink, pre-configuration step 17 in section 4.1.3 must have been performed.
Repeat the configuration steps of the Primary on Secondary unit.
Repeat the configuration steps of the Primary on Secondary unit.