3.  Without moving the Primary unit, adjust the azimuth and elevation angle of the Secondary 
unit for maximum link quality. Link quality is to be monitored via a unit’s Link Setup Meter 
as described in the previous section  
4.  Without moving the Secondary unit adjust the azimuth and elevation angle of the Primary 
unit for maximum link score 
5.  Repeat steps 3 and 4 to fine tune the alignment. Note: If the installation is in a complete 
NLoS situation, repeat the alignment process by pointing the Primary antenna in different 
directions for maximum CINR reading on the Secondary unit. 
6.  Once the alignment process is complete and the best signal quality is achieved, secure the 
Primary and Secondary units by tightening the mounting screws 
5.2  System configuration 
After the Primary and the Secondary units are preconfigured and installed, connect to both units 
from a Management PC on the Management network. The Management PC needs to have an IP 
address on the Management network to be able to communicate through the pre-configured 
Management IP gateway. To verify connectivity from a terminal window, issue the ping command 
as follows: 
➢ 
ping [M4-2000 unit’s assigned IP address] 
Once connectivity is established, open a browser window on the Management PC and enter the 
target unit’s IP address in the URL field. On the Login page enter the pre-configured Name and 
Password. The Main management page will open, which provides a summary of unit status, state 
and configuration information. To further configure the unit, follow the configuration pages from 
the main menu on the left side of the Main page.  Please see Section 6 for configuration options.  
Following configuration of the Primary unit, connect to the Secondary (remote) unit by entering its 
IP address in the URL address field. Note that in order to be able to connect to the remote unit 
management over the airlink, pre-configuration step 17 in section 4.1.3 must have been performed. 
Repeat the configuration steps of the Primary on Secondary unit.