ICOM 375410 Manuale Utente

Pagina di 68
32
6
SCANNING
6
201802
201802
BASIC MANUAL
 
VFO scan
The VFO scan searches for a signal within 
the specified frequency range.
 
L
See 
page 31
 for details of ‘Starting or 
canceling the scan.’
 
D
Full scan (ALL)
Repeatedly scans the entire band.
IC-R30 frequency
lower end
IC-R30 frequency
upper end
Scan
Jump
PSKIP
PSKIP
 
D
Band scan (BAND)
Repeatedly scans the selected band.
Band frequency
lower end
Band frequency
upper end
Scan
Jump
PSKIP
PSKIP
 
D
Program scan (P00 ~ P49)
Repeatedly scans the selected Program 
Scan range (P-Scan Edge 00 ~ 49). 
Scan
Jump
Jump
Scan range
Lower edge
Upper edge
PSKIP
PSKIP
 At least one Program Scan range (P-Scan 
Edges) must be entered to start a Program 
scan.
([MENU] > Scan > 
P-Scan Edge)
See 
page 33
 for more details.
 
D
Program Link scan  
(P-LINK 0 ~ 9)
Sequentially scans the Program Scan 
ranges. The links are set on the MENU 
screen. ([MENU] > Scan > 
Program Link)
See 
page 34
 for more details.
Program scan edges (Example: P00 ~ P10)
Jump
Scan
P00 P01 P02 P03
P10
 
L
While scanning, push [BAND] to move to 
the next Program scan range.
 
D
Auto memory write scan 
(Auto MW)
When a signal is received during a VFO 
scan, the frequency is automatically stored 
into an Auto Memory Write channel group 
(A000 ~ A199).
Scan
Signal received
Jump
Scan range
A000
Channels
A002
A001
A199
 
L
Information
 •The Auto Memory Write scan writes 
to a memory channel when the scan 
automatically resumes.
 •When no blank channels is left in the 
Auto Memory Write channel group A 
(000 ~ 199), the scan automatically 
cancels.
 •When you start this scan, you can 
skip the following dialog in the Menu 
screen.
    “ Clear All memories in the group A? 
(The Auto MW Scan will then start.)
( [MENU] > Scan > 
Auto MW SCAN 
Memory Clear)
OFF:  Writes to a blank channel in the group 
A.
Display Dialog: Display dialog to confirm. 