Laser beta lasermike LS8000-3 Manuale Utente

Pagina di 221
LaserSpeed 8000-3 Instruction Handbook
 
Installing the System 
 
 
Part No. 93463 / Drawing No. 0921-01561 
Page 19 of 221 
Revision A (Sep 2007) 
for more details. When mounting the gauge, be aware of the environment in 
which the gauge is operating. Steam, mist, coolant on the material, ambient 
temperature, scale and slag may all affect the performance of the gauge. 
These environmental conditions may need to be modified as mentioned above 
in order to maximize the performance of the gauge. 
Mounting Location 
When mounting the gauge over the 
material, be sure the gauge is not 
directly over a roller or some other 
device. If the laser beam from the gauge 
strikes an object, it may detect a false 
Material Present. In this case, the gauge 
will not be able to detect when the 
actual material is not in the 
measurement volume. 
A device that captures most of the laser 
light is called a beam dump and may be 
required (see figure). A suitable beam 
dump is a large-diameter pipe, 150 
millimeters (6 inches) or larger, angled 
at 45° from the laser beams. A rusty 
pipe is an excellent beam dump. If scale 
can deposit in the base of the beam 
dump, the pipe may need to be cleaned 
periodically to prevent false Material 
Present readings.  The beam dump 
should be far enough from the gauge 
that it cannot be measured.  A good guideline is to place the beam dump at 
least double the standoff distance from the gauge. 
 
 
 
 
 
 
 
PASSLINE
Standoff
Distance
Rollers
Standoff
Distance
Cut at 45
º
Beam Dump
Open Both Ends