FMC Corporation - Talstar FMC L06 Manuale Utente

Pagina di 65
Doc No: OMM50000903 
Rev:  B  Page 7 of 65 
Subject to contractual terms and conditions to the contrary, this document and all the information contained herein are the confidential and exclusive  
property of FMC Technologies, and may not be reproduced, disclosed, or made public in any manner prior to express written authorization by FMC. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 2: L06 – L16 Pump Assembly with No Pinion Shaft (Includes HD & HV) 
Choice of straight keyed shaft or 
mounting flange for direct coupling 
(splined shaft) of hydraulic motors 
(shown). 
Oil level sight gage allows 
remote monitoring of oil level 
and condition. 
 
Heavy-duty power ends are machined from a one-
piece gray iron casting for long trouble free life.  All 
pumps incorporate a reliable splash lube system with 
gravity feed return to sump.  
Two-bolt cover 
clamps or 
threaded covers 
for easy access 
to valves 
Abrasion resistant (AR) or disc type 
valves feature tough, durable 
materials and generous flow areas to 
extend service life.  Ball type valves 
are available for fluids with solids that 
will foul conventional valves and 
restrict flow. 
NPT threaded ports 
are standard. 
Many piston and liner combinations are offered to 
provide maximum service life for each application.  
Liner wash is available for extending piston and 
liner life. 
Integrally cast and 
machined feet to provide 
rigid and precise mounting 
Magnetic drain 
plugs remove 
tramp iron from 
the oil bath. 
Fluid ends are designed for years of service 
in demanding applications.  Standard 
materials of construction are cast ductile iron 
or nickel aluminum bronze.  Fluid end design 
allows for very low clearance volumes to 
improve both volumetric efficiency and the 
pumps ability to prime. 
Individually clamped 
cylinder covers on 
most models allow 
easy access for 
service needs. 
FMC Nameplate