VENTING INSTALLATION
Continued
CHECKING FOR PROPER VENTING
After  completing  and  checking  electrical, 
gas  and  vent  connections,  follow  lighting 
instructions.and.allow.main.burner.to.run.for.
approximately. 5. minutes.. Hold. a. match. or.
butane lighter flame, near opening between 
glass  and  fireplace  face  and  play  it  along 
entire.length.of.opening.(Smoke.may.also.be.
used). Proper venting will tend to draw flame 
or  smoke  into  appliance.  Improper  venting, 
escaping  or  spillage  of  burned  gas,  is  indi-
cated when match flickers or goes out (see 
Figure.1)..Smoke.will.also.tend.to.disperse.
away.from.appliance.
If appliance is not venting properly, shut it off 
and notify your installer or a qualified service 
agency.to.inspect.venting.system.
Figure 12 - Checking for Spillage
Figure 13 - Relocating Junction Box Recep-
tacle and Electrical Supply Connection
ELECTRICAL SUPPLY CONNECTION
  CAUTION:  Disconnect  the 
electrical  power  to  the  supply 
circuit before attempting to con-
nect or service this appliance.
A prewired junction box receptacle with strain 
relief.is.provided.on.right.side.of.cabinet.for.
hard wiring unit to a 15 Amp, 120 VAC, 60 Hz 
grounded.branch.circuit..If.installation.demands.
electrical supply be connected from the left, the 
entire.receptacle.box.can.be.relocated.to.the.
left.side.by.following.these.instructions:
J-Box.
Cover.
with.Strain.
Relilef
J-Box.
Cover
Romex.
Cable
J-Box.with.
Receptacle
J-Box.Cover.
with.Strain.
Relief
Screw/Tab.
Retainer
Note: If you do not need to relocate the junc-
tion box, to connect the electric supply follow 
steps 8 through 11 only:
1.. Remove..screws.and.outer.cover.with.
strain.relief.bushing.on.right.side.of.cabi-
net.(see.Figure.13).
2.  Remove inner retaining screw on junction 
box.mounting.tab.
3.  Slide junction box up until screw mounting 
tab.is.lined.up.to.notch.in.outer.cabinet.
4.  Swing junction box out and slip retaining 
flange out through slot in outer cabinet.
5.. Remove..screws.and.outer.cover.on.left.
side.of.outer.cabinet.
6.  Reinsert  junction  box  retaining  flange 
through.slot.now.on.left.side.and.swing.
screw.mounting.tab.back.through.notch.
as.before.
7.  Slide junction box down till mounting tab 
holes.line.up.and.replace.inner.retaining.
screw.
8.  With  junction  box  cover  removed,  pull 
end.of.3-wire.Romex.supply.line.through.
universal. strain. relief. bushing. on. cover..
(see.Figure.13).
9.. Strip.back.outer.Romex.to.about.4".and.
connect black, white and green wires ac-
cordingly.using.3.wire.nut.connectors.
10. Tuck  tailing  wires  into  junction  box  and 
replace junction box cover using 2 remain-
ing.screws.
11. Tighten  adjustment  on  universal  strain 
bushing.to.secure.Romex.sheathing.and.
complete.supply.connection.