Desa CB36P ユーザーズマニュアル

ページ / 36
www.desatech.com
117437-01D
1
  WARNING:  This  appliance, 
when installed must be electri-
cally  grounded  in  accordance 
with  local  code  or  in  the  ab-
sence  of  local  code,  with  the 
current National Electric Code, 
ANSI/NFPA 70, or the Canadian 
Electric Code, CSA C22.1.
HIGH ALTITUDE INSTALLATION
Your DESA Heating, LLC direct-vent fireplace 
has  been  tested  and  approved  in  the  USA 
for elevations from 0-2,000 feet (610 m) and 
in  Canada  at  elevations  from  0-4,500  feet 
(1,372 m).
VENTING INSTALLATION
Continued
9-Volt.
Alkaline.
Battery
Receiver
Terminal.
Wires
Battery.Clip
Figure 15 - Attaching Alkaline Battery to 
Receiver
When installing a non-high altitude fireplace 
at an elevation above 2,000 feet (610 m) (in 
the USA), you may need to decrease the input 
rating by changing the existing burner orifice 
to a smaller size. Reduce input 4% for each 
1,000  feet (305  m) above  sea level.  Check 
with your local gas company for proper orifice 
size identification.
When installing this fireplace in Canada at an 
elevation above 4,500 feet (1,372 m), Check 
with.local.or.provincial.code.authorities.
Consult.your.local.gas.company.to.help.deter-
mine the proper orifice for your location.
For.assistance.with.any.high.altitude.installa-
tion contact DESA Heating, LLC’s Customer 
Service.Department.at.1-866-67-6040.
INSTALLING OPTIONAL CONTROLS
INSTALLING OPTIONAL WALL 
MOUNT SWITCH - GWMS2
1.. Connect.one.terminal.of.15.foot.wire.from.
wall.switch.to.male.connector.on.high.limit.
harness..Connect.remaining.wire.terminal.
to.TH.terminal.on.valve..Make.sure.that.
wire.terminals.are.in.positions.on.unit.as.
pictured.in.Figure.14..If.wires.are.not.con-
nected.as.shown.switch.will.not.work.
.. Route.15.foot.wire.through.hole.openings.
with.bushings.provided.on.either.side.of.
fireplace cabinet.
3.. Connect. one. bare. wire. end. to. each. of.
terminals.of.GWMS.wall.switch.
4.. Install.wall.switch.and.cover.in.wall.
IMPORTANT:.Do.not.use.any.other.wire.than.
that.provided.with.GWMS.wall.switch.kit..Do.
not.exceed.15.feet.of.distance.from.valve.con-
nection. Using wire of higher gauge or turns 
or.exceeding.minimum.distance.will.increase.
resistance.at.control.valve.causing.unreliable.
performance of fireplace controls.
INSTALLING OPTIONAL WIRELESS 
HAND-HELD REMOTE CONTROL 
MODEL HRC100
Installing Remote Receiver
1.. Open.bottom.louver.and.locate.switch.
bracket.on.right.side.
.. Locate. battery. clip. mounted. on. back. of.
receiver.. Slide. a. 9-volt. alkaline. battery.
(not.included).through.clip.
3.. Attach. terminal. wires. to. battery. (see.
Figure.15).
Remote Receiver
or Wall Switch to
Terminal Marked “TH”
Wire Harness From
High Limit Switch
Male Connector to
Remote Receiver
or Wall Switch
Figure 14 - Connecting Remote Receiver 
or Wall Switch to the Gas Control Valve