Korg Electric Keyboard ユーザーズマニュアル

ページ / 269
86
7.2–1b: Master FX Chain
MFX Chain
[Off, On]
Direction (Chain Direction)
[MFX1
MFX2, MFX2
MFX1]
Signal (Chain Signal)
[LR Mix, L Only, R Only]
Level (Chain Level)
[000...127]
This is the same as in Program mode. Refer to “PROG 7.2–1: 
Setup.”
7.2–1c: MEQ Ctrl
MEQ Ctrl (MEQ Control Ch)
[Ch01...16, G ch]
Specifies the MIDI channel that will control dynamic 
modulation (Dmod) for the master EQ.
G ch
: The effect will be controlled on the global MIDI chan-
nel “MIDI Channel” (GLOBAL 2.1–1a).
7.2–1d: Master EQ Gain [dB]
Low
[–18.0...+18.0]
Mid
[–18.0...+18.0]
High
[–18.0...+18.0]
This is the same as in Program mode. (☞PROG 7.2–1: Setup)
 7.2–1e: UTILITY
☞ “Memory Status,” “Solo Selected Track,” “FF/REW 
Speed,” “Set Location” (1.1–1d), “Select by Category” 
(PROG 7.2–1d)
Copy Master Effect
☞p.28 PROG 7.2–1d
Note, the MIDI control channel specified in “Control Chan-
nel” of the MFX 1 and 2 pages will not be copied.
Swap Master Effect
☞p.29 PROG 7.2–1d
Note, the MIDI control channel specified in “Control Chan-
nel” of the MFX 1 and 2 pages will not be swapped.
7.2–2: MFX1
 (Master Effect1)
7.2–3: MFX2 
(Master Effect2)
Here you can set the parameters of the “Master Effect1” and 
“Master Effect2” effects that were selected in the Setup page 
(☞p.164–).
 7.2–2(3)a: UTILITY
☞ “Memory Status” (1.1–1d)
7.2–4: MEQ
 (Master EQ)
The master EQ is a three-band stereo EQ. It is used to per-
form overall equalizing (tonal adjustment) on the sound 
from the L/R bus immediately before it is output to AUDIO 
OUTPUT (MAIN OUT) L/MONO and R (☞p.209).
 7.2–4a: UTILITY
☞ “Memory Status” (1.1–1d)
7.2–2a
7.2–4a