ADjuStMentS
The following checks, and possible adjust-
ments, should be done in the order listed 
before beginning operation.
WARnIng: For safety, unplug the line 
cord to the Radial Arm Saw.
Tables A (127), B (126), and C (125) 
1. 
are checked for straightness at the 
factory. 
However, changes in humidity can 
slightly alter the condition of the 
wood. With the Screw Clamps (131) 
tightened, use a straight edge or 
framing square to check for flatness 
and squareness. Sand down any high 
spots using fine sandpaper.
Check for Arm tightness on the Col-
2. 
umn (132). If loose, tighten Bolt (115).
3.  Check the crosscut travel of the Saw 
Blade for squareness. 
- Lock or tighten all adjustment levers 
and knobs. 
- Lower the Arm until it just clears the 
Table A front. 
- Place a framing square so it just 
touches a tooth of the Saw Blade. 
- Mark this location with a pencil on 
the table and draw a straight line us-
ing the square. 
- Check that the Saw blade follows 
this line from front to back. 
If the Saw Blade moves to the right 
or left side of the line as it travels the 
entire length of the Arm, loosen the 
Screw Clamps (137) and lightly tap 
on the Table left or right side until 
there is full travel alignment. Tighten 
the Screw Clamps again.
4.  Check that the Saw Blade is square 
to Table A. 
- Place a framing 
square on Table A 
so that the square 
is flat on the Saw 
Blade (not touching 
teeth). 
- If there is no gap between the 
square and the Saw Blade, no adjust-
ment is necessary. 
- If the square does not touch the 
Saw Blade evenly (with the square 
flat on the Table A), loosen the Bevel 
Lock Knob (71) and adjust the motor 
until the gap between Saw Blade and 
the square is eliminated.
5.  Check that the Saw Blade is square 
to the rip fence. 
- Firmly place a 
framing square 
against the rip 
fence and the blade 
as shown to the 
right. The square 
should not touch any teeth. 
- If the square is not flush with the 
entire blade, loosen the yoke 
pivot Clamp Handle (66) and move 
the motor assembly until any gaps 
have been eliminated. Tighten the 
Yoke Pivot Clamp and recheck align-
ment. (This will simultaneously set 
both yoke indexing positions for in 
and out ripping.)