Bosch TES 50129 RW ユーザーズマニュアル

ページ / 117
21
TES501..   08/2011
en
Simple troubleshooting
Problem
Cause
Remedy
Coffee is too “bitter”.
The grind setting is too fine 
or the pre-ground coffee is 
too fine.
Adjust the grinding unit to 
a coarser setting or use 
coarser pre-ground coffee.
Unsuitable type of coffee.
Change the type of coffee.
The water filter does not 
stay in position in the water 
tank (16).
The water filter is not fitted 
correctly.
Firmly press the water filter 
straight down into the tank 
connection.
The coffee grounds are not 
compact and are too wet.
The grind setting is too 
fine or too coarse, or not 
enough ground coffee has 
been used.
Adjust the grinding unit to 
a coarser or finer setting, 
or use 2 level measuring 
spoons of ground coffee.
LED 
I
 flashes.
Brewing unit  (5) is soiled.
Cleaning the brewing   
unit (5).
Too much pre-ground cof-
fee in the brewing unit (5).
Clean the brewing unit (5)
(Put in no more than 2 
level measuring spoons of 
ground coffee).
The brewing unit mecha-
nism is stiff.
Remove the brewing unit 
and treat with a special 
grease intended for this 
purpose (order  no. 311368), 
see “Maintenance and daily 
cleaning”.
Coffee or milk froth quality 
varies widely. 
Build-up of limescale in the 
appliance.
Descale the appliance with 
two descaling tablets as de-
scribed in the instructions.
Water dripped onto the in-
ner floor of the appliance 
when the drip tray (8) was 
removed.
Drip tray (8) removed too 
soon.
Wait a few seconds after 
the last drink was dis-
pensed before removing the 
drip tray (8).
LED 
I
 lights up.
Brewing unit (5) is missing 
or has not been detected.
Switch off the appliance 
with the brewing unit (5) in 
place, wait three seconds 
and switch on the appliance 
again.
If you are unable to solve the problem, please call the hotline.
TES501_Heft1_RW.indb   21