Bosch TES 50129 RW ユーザーズマニュアル
Robert Bosch Hausgeräte GmbH
22
en
Problem
Cause
Remedy
The default settings have
been changed and need to
be reset.
Some settings have been
made that are no longer
required.
Press the power on/off but-
ton
O / I (9) to switch off the
appliance. Press and hold
the service button (12) and
the steam button (11) and
press the power on/off but-
ton
O / I (9) to switch on the
appliance. Then press the
start button (10) to confirm.
The default settings are
reset.
LEDs
flash.
The appliance has a fault.
Please contact the hotline.
LEDs
flash.
Incorrect voltage.
Operate the appliance at
220 V-240 V only.
LEDs
flash.
The ambient temperature is
too cold.
Operate the appliance at
temperatures > 5° C.
If you are unable to solve the problem, please call the hotline.
Simple troubleshooting
Technical specifications
Electrical connection (voltage/frequency)
220-240 V / 50-60 Hz
Heating output
1600 W
Maximum pump pressure, static
15 bar
Maximum water tank capacity (without filter)
1.7 l
Maximum bean container capacity
300 g
Cable length
100 cm
Dimensions (H x B x D)
385 x 280 x 479 mm
Weight, unfilled
9.3 kg
Type of grinding unit
Ceramic
TES501_Heft1_RW.indb 22
14.09.2011 16:10:31