Chapter 4        Troubleshooting 
 
 
 
92 
 
No Reverse RF Signal 
The reverse RF signal can be measured at the line extender module reverse input 
and reverse output test points. 
 
No Reverse RF Signal Troubleshooting Table 
Before you begin troubleshooting for no reverse RF signal, verify that the line 
extender is receiving the proper reverse RF input signals from the downstream line 
extender at the line extender reverse input test point. 
Important: You cannot balance the line extender without the proper reverse RF 
input signals. 
Possible cause 
Solution 
No reverse RF signal at the reverse 
input test point. 
 
Verify that the line extender is receiving the 
proper reverse RF input signals from the 
downstream line extender. 
Important: You cannot balance the line 
extender without the proper reverse RF input 
signals. 
There is a proper reverse RF signal at 
the reverse input test point, but no 
signal at the reverse output test 
point. 
 
Verify that the line extender module is 
receiving the proper AC and DC voltages. 
Refer to No AC Power (on page 85) and No DC 
Power
 (on page 87). 
 
Verify that the line extender module is 
receiving the proper forward RF signal. Refer 
to No Forward RF Signal (on page 89). 
 
Verify that all the proper accessories, pads, and 
EQs are firmly installed in the correct locations. 
 
Verify that the factory installed accessories are 
firmly installed in the correct locations. 
 
Verify that the reverse switch (if applicable) or 
its jumpers are properly and firmly installed. 
Note: Verifying factory installations involves 
removing the line extender module cover. 
Reinstall the line extender module cover 
properly or RF signal degradation may result. 
 
Replace the line extender module.