Canon ir2016, ir2020 マニュアル

ページ / 42
Chapter 3
5
Chapter 3  Error Code
3.1 Error Code Details
3.1.1 Error Code Details
0011-2580
iR2016J / iR2016 / iR2020 /  / iR2016i / iR2020i
T-3-1
Display 
Code
Detail Code
Main Cause/Symptom
Countermeasure
E000
0000
Startup error
The temperature detected by the main 
or sub thermistor does not rise to the 
specified value during startup control.
- Check the fixing film connector.
- Replace the fixing film unit.
- Replace the DC controller PCB. 
E001
0000
Abnormally high temperature (detected by main thermistor)
The main thermistor detected an 
abnormally high temperature (240 deg 
C) during temperature control. 
- Check the connector of the fixing film unit.
- Replace the fixing film unit. 
- Replace the DC controller PCB.
0001
Abnormally high temperature (detected by sub thermistor) 
The sub thermistor detected an 
abnormally high temperature (295 deg 
C) during temperature control.
- Check the connector of the fixing film unit.
- Replace the fixing film unit.
- Replace the DC controller PCB.
E002
0000
Low temperature during temperature control. 
The target temperature is not reached 
during temperature control.
- Check the connector of the fixing film unit.
- Replace the fixing film unit.
- Replace the DC controller PCB.
E003
0000
Abnormally low temperature (detected by main thermistor)
After the temperature detected by the 
main thermistor has reached the 
specified value, it does not reach the 
specified value during initial rotation.
- Check the connector of the fixing film unit.
- Replace the fixing film unit.
- Replace the DC controller PCB.
0001
Abnormally low temperature (detected by sub thermistor) 
After the temperature detected by the 
sub thermistor has reached the 
specified value, it does not reach the 
specified value during initial rotation.
- Check the connector of the fixing film unit.
- Replace the fixing film unit.
- Replace the DC controller PCB.
E007
0000
Fixing film sensor failure
The fixing film sensor is faulty. 
- Check the connector of the fixing film 
sensor. 
- Replace the fixing film sensor.
- Replace the DC controller PCB.
E010
0000
Main motor failure
The main motor is faulty. 
- Check the connector of the main motor. 
- Replace the main motor.
- Replace the DC controller PCB.
E019
0000
Waste toner full detection 
The waste toner full state was detected. Replace the drum unit.
0001
Waster toner full detection sensor is faulty. 
The waste toner full state was detected 
continuously for five or more seconds 
while the main motor was turning.
- Check the connector of the waster toner full 
sensor. 
- Replace the waste toner full sensor.
- Replace the DC controller PCB.
E052
0000
Erroneous connection to duplex unit 
Disconnection of the duplex unit was 
detected after power-on, detection of 
normal connection to the duplex unit, 
and start of communication. 
- Check the connectors of the duplex unit and 
DC controller PCB. 
- Replace the duplex controller PCB. 
- Replace the DC controller PCB.
E100
0000
BD detection PCB failure 
The BD detection PCB is faulty.  
- Check the connector of the BD detection 
PCB. 
- Replace the laser scanner unit. 
- Replace the DC controller PCB.
E197
0000
Printer engine communication error 
Erroneous communication between the 
DC controller PCB and image 
processor PCB was detected.
- Check the connectors of the DC controller 
PCB and image processor PCB. 
- Replace the DC controller PCB for normal 
connection.
- Replace the image processor PCB. 
E716
0000
Erroneous communication with optional cassette
Disconnection of the optional cassette 
was detected after power-on, detection 
of normal connection to the optional 
cassette, and start of communication. 
- Check the connectors of the optional cassette 
PCB and DC controller PCB.
- Replace the optional cassette PCB for 
normal connection.