MAINTENANCE
GENERAL
Hatco Flav-R-Savor
®
Tall Humidified Holding
Cabinets are designed for maximum durability and
performance, with minimum maintenance.
WARNING
To avoid any injury, turn the power switch OFF,
unplug the unit from the power source and allow
to cool completely before performing any
maintenance or cleaning.
WARNING
To prevent any injury, discontinue use if power
cord is frayed or worn.
CLEANING
To preserve the bright finish of the Flav-R-Savor Tall
Humidified Holding Cabinet, it is recommended that
the exterior and interior surfaces be wiped daily with
a damp cloth. Food pans should be removed and
washed. Stubborn stains may be removed with a
good stainless steel cleaner or a non-abrasive
cleaner. Hard-to-reach areas should be cleaned
with a small brush and mild soap.
WARNING
To  avoid electrical shock or personal injury, do
not steam clean or use excessive water on the
unit.
CAUTION
Use only non-abrasive cleaners. Abrasive
cleaners could scratch the finish of your
Flav-R-Savor cabinet marring its appearance
and making it susceptible to soil accumulation.
Clean the Lexan door using a damp cloth or
common glass cleaner.
NOTE: FSHC series blower motor is permanently
lubricated and requires no maintenance.
DRAINING THE WATER  PAN
WARNING
To  avoid any injury, turn the power to the unit
OFF and allow to cool before draining.
It is recommended that the Flav-R-Savor water pan
be drained after removing lime or mineral deposits
from the water reservoir.
Note: Position unit near a sink/drain and or use a
container to hold the water while draining.
Lift heat tunnel straight up from housing, located
on bottom of the cabinet then pull towards the
front of the unit to remove.
Element sets inside the water pan. Element is
hinged. Rotate element upward to remove the
water pan out of the way and slide pan out.
Discard water and clean pan and water baffle.
NOTE: When installing the water pan, make sure the
water heating element is laying flat in the water pan,
between the water baffle and is not tilted up.
1.
2.
3.
Water 
Reservoir 
Heat 
Tunnel
Tunnel 
Lifts Up 
and 
Out
Rotate Element
Upward to 
Slide 
Water Pan
Heat 
Tunnel 
Alignment 
Pins
Heat 
Element is 
Hinged
Water Pan Alignment Pins
Water 
Baffle
Figure 14. Water Reservoir and Heat Tunnel
Form No. FSHC17WM-0506
9