DSC pc1616 ユーザーズマニュアル

ページ / 64
Section 2: User Commands
7
[4][6] – User Functions
Press [4][6] followed by the Master Code, then press the number corresponding to the following functions.
Additional Alphanumeric Keypad Functions:
When scrolling through the list of available functions, the following additional functions are available:
Event Buffer:
Used to view the 500-event panel buffer
Brightness Control:
Used to adjust the display backlighting level for optimal viewing
Contrast Control:
Used to adjust the display contrast level for optimal viewing
Buzzer Control:
Used to adjust the keypad buzzer tone for optimal sound 
[4][7][x] – Command Output (1-4)
Press [4][7][x].  If the Command Output Code Required option is enabled, enter a valid user code.  The panel will activate any PGM output 
assigned to the command output.
[4][8] – Installer Programming
Press [4][8] followed by the Installer Code to enter Installer Programming.  Refer to the ‘How to Program’ section for more information.
[4][9][User Code] – No-Entry Arming
Press [4][9] followed by a valid user code.  The system will arm in the Stay mode and after the exit delay expires, it will remove entry delay.  
All zones programmed as Delay will function like Instant zones.  The system will flash the Armed light to indicate that the system is armed 
with no entry delay.
[4][0] – Quick Arm/Quick Exit
Quick Arm: When disarmed, press [
4
][0] to arm the system.  The system will arm as if a valid user code was entered.
Quick Exit: When armed, press [
4
][0] to activate Quick Exit.  The system will allow a single zone programmed as Delay to be violated 
once during the following 2 minute time period without changing the status of the system.
Section 2.5 – Function Keys
Keypads have 5 programmable one-touch function buttons located in a column down the right-side of the keypad.  These buttons can also be 
activated by pressing and holding number [1] through [5] respectively for 2 seconds.  The default for these function buttons on the PK series 
keypads are as follows:
[1]
Stay Arm
[4]
Fire Reset – Command Output 2
[2]
Away Arm
[5]
Quick Exit
[3]
Chime Enable/Disable
[1]
Program Time and Date:  Enter the time and date using the following format [HH:MM] [MM/DD/YY].  Program the time using 
military standard (e.g., 8:00 pm = 20:00 hours).
[2]
Auto-arm Enable/Disable:  The keypad will emit 3 rapid beeps if the Auto-arm feature is now enabled and a steady 2-second tone 
if it is now disabled.  
[3]
Auto-arm Time/Day:  Press the number corresponding to the day of the week (1=Sunday, 2=Monday etc.) followed by the auto- 
arm time.  Program the time using military standard (e.g., 8:00 pm = 20:00 hours).
[4]
System Test:  The panel will perform the following; activate the bell output, keypad buzzer and all keypad status lights for 2 
seconds, test the backup battery and transmit a reporting code to the central station (if programmed).
[5]
Enable DLS:  The panel will temporarily enable DLS for 6 hours.
[6]
User Initiated DLS:  The panel will attempt to call the DLS computer.
[7]-[8]
For Future Use
 For LCD Keypads: Scroll to the desired option then press [4]
For the PC5508, PC5516, PC5532 and LCD5501 LED keypads, Press and hold the [4] key to adjust the keypad 
buzzer tone, then release the button. For the PK series keypads, enter [4][6][Master Code] then use the left arrow 
button (<) to scroll to the desired buzzer tone and use the right arrow button (>) to adjust the backlighting level.  
When finished, press [#] to exit.