5.5 Final installation
WARNING: Swim Alert™ is liable to set off its siren during the various operations. It is therefore strongly
recommended to switch to OFF mode (see §7.6) so that it can be freely handled during its final installation.
-
Pull back the rigid angled tube by a few inch to release the cover (Pict. 9)
-
Remove the cover from your fall detector.
-
Locate the 3 holes at the bottom of the base.
-
Position the base on your coping so that the rigid angled tube is more than 0,2 in away from the coping.
-
Using a felt-tip pen, mark the position of the holes to be drilled in the coping through the 3 holes in the base
(Pict. 10)
(Pict. 10)
-
Remove the base from the coping.
-
Drill the 3 holes in the coping with a Ø 0.3 in. bit and set the rawplugs in place (Pict 11 & 12).
-
Place the 3 stabilizing foam pads under the base, at the appropriate locations (Pict. 13)
.
-
Position and fasten the base using the 3 screws and the 3 washers (the 3 washers are inside the box).
Do not
crush completely the stabilizing foam pads while screwing (Pict. 14).
-
Position the 4 small black joints on the base screw barrels (Pict. 15)
Pict. 9
Pict. 10
Pict. 12
Pict. 11