SmartSight Networks Inc MF24 ユーザーズマニュアル
35
_____________________________________________________________________________________________
Microflex AV/ADV/AVr/ADVr North-American user’s manual / Rev 1.4
• PER (Packet Error Rate)
The error rate (number of errors / total number of packets) expressed in a
scientific format
scientific format
Figure 17 – Diagnostic window
At any time, the test can be reset by clicking the “Reset” button or aborted by
clicking the “Close” button.
___________________________________________________________________
The diagnostic is not available on a Microflex in Master mode. A Microflex in Slave mode
must be selected to enable the diagnostic feature.
___________________________________________________________________
The diagnostic is not available on a Microflex in Master mode. A Microflex in Slave mode
must be selected to enable the diagnostic feature.
___________________________________________________________________
4.6 Firmware Update
MNM supports Microflex upgrades anywhere in the network. The Microflex A/AD
must have the following firmware modules loaded to be fully functional:
Microflex main program:
must have the following firmware modules loaded to be fully functional:
Microflex main program:
Most recent version
Audio application program:
Most recent version
Audio G.729AB CODEC:
Most recent version
Radio main program:
Most recent version
Radio loader program:
Most recent version
To perform a firmware update of any of these modules, follow the few steps below:
(a) Select the unit to update in the network list (local or remote).
(b) Select the appropriate firmware file in the File menu either by browsing
(b) Select the appropriate firmware file in the File menu either by browsing
the disk drives or by selecting a previously used filename.
(c) Proceed to the firmware update.
___________________________________________________________________
If the module has been set to loader mode (see Chapter 1) it will not be possible to see the
Microflex in the MNM list. In this case proceed to the firmware update without a module
selected. An error window will appear (figure 18). At this point, you can proceed with the
update if you are locally connected to the unit in loader mode. To do so, select “Yes”.
If the module has been set to loader mode (see Chapter 1) it will not be possible to see the
Microflex in the MNM list. In this case proceed to the firmware update without a module
selected. An error window will appear (figure 18). At this point, you can proceed with the
update if you are locally connected to the unit in loader mode. To do so, select “Yes”.