4.2.2 
Altitude 
This option sets the proper altitude that the system will be used. Available settings include: [300m or less], 
[301m-900m], [901m-1500m], [Above 1500m].  
 
Selecting an altitude range that is lower than the actual altitude the system will be operating at, can cause the 
fan control system to operate less efficiently, leading to higher system thermals and lower system performance. 
If the altitude range selected is higher than the actual altitude the system will be operating at, the fan control 
system may provide better cooling but with higher acoustics and higher fan power consumption. If the altitude 
is not known, selecting a higher altitude is recommended in order to provide sufficient cooling.  
4.2.3 
Set Fan Profile 
This option sets the desired Fan Profile.  Available settings include: 
[Performance] and [Acoustic].  
 
The Acoustic mode offers the best acoustic experience and appropriate cooling capability supporting the 
majority of the add-in cards used. Performance mode is designed to provide sufficient cooling capability 
covering all kinds of add-in cards on the market.  
4.2.4 
Fan PWM Offset 
This option is reserved for manual adjustment to the minimum fan speed curves. The valid range is from [0 to 
100] which stands for 0% to 100% PWM adding to the minimum fan speed.   This feature is valid when Quiet 
Fan Idle Mode is at Enabled state. The default setting is [0] 
4.2.5 
Quiet Fan Idle Mode 
This feature can be [Enabled] or [Disabled]. If enabled, the fans will either shift to a lower speed or stop when 
the aggregate sensor temperatures are satisfied, indicating the system is at ideal thermal/light loading 
conditions. When the aggregate sensor temperatures are not satisfied, the fans will shift back to normal control 
curves. If disabled, the fans will never shift into lower fan speeds or stop, regardless of whether the aggregate 
sensor temperatures are satisfied or not. The default setting is [Disabled]  
 
Note: The above feature may or may not be in effect and depends on the actual thermal characteristics of the 
specified system.  
 
4.2.6 
Thermal Sensor Input for Fan Speed Control 
The BMC uses various IPMI sensors as inputs to fan speed control. Some of the sensors are actual physical 
sensors and some are “virtual” sensors derived from calculations.  
 
The following IPMI thermal sensors are used as input to fan speed control: 
 
•  Front Panel Temperature Sensor
1
  
•  CPU Margin Sensors
2,4,5
 
•  DIMM Thermal Margin Sensors
2,4
 
•  Exit Air Temperature Sensor
1, 7, 9
 
•  PCH Temperature Sensor
3,5
 
•  On-board Ethernet Controller Temperature Sensors
3, 5
 
•  Add-In Intel SAS/IO Module Temperature Sensors
3, 5
 
•  PSU Thermal Sensor
3, 8
 
•  CPU VR Temperature Sensors
3, 6
 
•  DIMM VR Temperature Sensors
3, 6
 
•  BMC Temperature Sensor
3, 6
 
•  Global Aggregate Thermal Margin Sensors
 7 
 
•  Hot Swap Backplane Temperature Sensors 
•  I/O module Temperature Sensor (With option installed) 
•  Intel
®
 ROC Module (With option installed)