KVM-8 Installer/User Guide
14
On-Screen Display Operations
15
System Control and Maintenance
The following commands are used for system control and maintenance. Enter the 
command sequences to perform the actions described in the table below.
Key Sequence
Action
<CM>Kn<Enter>
Sets the keyboard scan set where n is a scan set number 1-3.
<CM>MR<Enter>
If you hot-plug your mouse cable, you may experience a loss of 
mouse signal. Use this command to restore the signal if you are 
using a PC with a standard PS/2 mouse driver.
<CM>MW<Enter>
If you hot-plug your mouse cable, you may experience a loss of 
mouse signal. Use this command to restore the signal if you are using 
a PC with a Microsoft IntelliMouse or other wheel mouse driver.
<CM>AV<Enter>
Displays the current firmware version of your KVM Switch.
<CM>SG<Enter>
Enables the scan Go command (by address only).
<CM>SH<Enter>
Enables the scan Halt command.
<CM>M+<Enter>
Enables mouse suspension of scanning.
<CM>M-<Enter>
Disables mouse suspension of scanning.
<CM>H1<Enter>
Changes the hot-key sequence to the default: (NumLock, -).
<CM>H2<Enter>
Changes the hot-key sequence to the 1st alternate: (NumLock, *).
<CM>H3<Enter>
Changes the hot-key sequence to the 2nd alternate:  (CTRL, ~).
<CM>OSD0<Enter>
Disables the OSD Sequence.
<CM>OSD1<Enter>
Changes the OSD sequence to the default: (CTRL, CTRL).
<CM>OSD2<Enter>
Changes the OSD sequence to the 1st alternate: (Alt, Alt).
<CM>OSD3<Enter>
Changes the OSD sequence to the 2nd alternate: (Shift, Shift).
<CM>ZM<Enter>
Use this command to resynchronize the mouse after a device or 
computer hot-plug. Repeat, if necessary, until synchronization is re-
established. 
Note:
 Using this command while the mouse is operating 
correctly will cause the mouse to lose sync.