ユーザーズマニュアル目次1. INTRODUCTION, FEATURES AND OPTIONS271.2. FEATURES271.3. OPTIONS282. SPECIFICATIONS, APPROVALS & COMPLIANCE312.1. SPECIFICATIONS312.2. EPA EQUIVALENCY DESIGNATION332.3. APPROVALS AND CERTIFICATIONS342.3.1. SAFETY342.3.2. EMC342.3.3. OTHER TYPE CERTIFICATIONS343. GETTING STARTED353.1. UNPACKING THE T400 ANALYZER353.1.1.1. Ventilation Clearance363.2. INSTRUMENT LAYOUT373.2.1. FRONT PANEL373.2.2. REAR PANEL413.2.3. INTERNAL CHASSIS LAYOUT433.3. CONNECTIONS AND SETUP443.3.1. ELECTRICAL CONNECTIONS443.3.1.1. Connecting Power443.3.1.2. Connecting Analog Inputs (Option)453.3.1.3. Connecting Analog Outputs453.3.1.4. Current Loop Analog Outputs (Option 41) Setup463.3.1.5. Connecting the Status Outputs483.3.1.6. Connecting the Control Inputs493.3.1.7. Connecting the Concentration Alarm Relay (Option 61)503.3.1.8. Connecting the Communications Interfaces523.3.2. PNENUMATIC CONNECTIONS583.3.2.1. About Zero Air and Calibration Gas583.3.2.2. Pneumatic Setup for Basic Configuration613.3.2.3. Pneumatic Setup for the T400 Analyzer with Internal Zero/Span Option (IZS)623.3.3. PNEUMATIC SETUPS FOR AMBIENT AIR MONITORING633.3.3.1. Pneumatic Set Up for T400’s Located in the Same Room Being Monitored633.3.3.2. Pneumatic Set Up for T400’s Monitoring Remote Locations643.4. STARTUP, FUNCTIONAL CHECKS, AND INITIAL CALIBRATION653.4.1. START UP653.4.2. WARNING MESSAGES653.4.3. FUNCTIONAL CHECK673.4.4. INITIAL CALIBRATION673.4.4.1. Interferents for O3 Measurement673.4.5. INITIAL CALIBRATION PROCEDURE FOR T400 ANALYZERS WITHOUT OPTIONS683.4.5.1. Verifying the T400 Reporting Range Settings683.4.5.2. Verify the Expected O3 Span Gas Concentration:693.4.5.3. Initial Zero/Span Calibration Procedure:713.5. CONFIGURING THE INTERNAL ZERO/SPAN OPTION (IZS)723.5.1. VERIFY THE O3 GENERATOR AND EXPECTED O3 SPAN CONCENTRATION SETTINGS723.5.2. SETTING THE O3 GENERATOR LOW-SPAN (MID POINT) OUTPUT LEVEL733.5.3. TURNING ON THE REFERENCE DETECTOR OPTION743.5.4. INITIAL CALIBRATION AND CONDITIONING OF T400 ANALYZERS WITH THE IZS OPTION INSTALLED753.5.4.1. Initial O3 Scrubber Conditioning753.5.4.2. Verifying the T400 Reporting Range Settings763.5.4.3. Initial Zero/Span Calibration Procedure:763.6. CALIBRATION VALVE OPTIONS763.6.1. AMBIENT ZERO/AMBIENT SPAN VALVES (OPT 50A)763.6.1.1. Pneumatic Setup for the T400 Analyzer with Zero/Span Valve Option783.6.2. INTERNAL ZERO SPAN (IZS) OPTION (OPT 50G)804. OVERVIEW OF OPERATING MODES854.1. SAMPLE MODE874.1.1. TEST FUNCTIONS884.1.2. WARNING MESSAGES904.2. CALIBRATION MODE914.3. SETUP MODE924.3.1. PASSWORD SECURITY924.3.2. PRIMARY SETUP MENU925. SETUP MENU955.1. SETUP ( CFG: CONFIGURATION INFORMATION955.2. SETUP ( DAS: INTERNAL DATA ACQUISITION SYSTEM965.3. SETUP ( ACAL: AUTOMATIC CALIBRATION OPTION965.4. SETUP ( RNGE: ANALOG OUTPUT REPORTING RANGE CONFIGURATION965.4.1.1. Physical Range versus Analog Output Reporting Ranges965.4.1.2. Analog Output Ranges for O3 Concentration975.4.1.3. RNGE ( MODE ( SNGL: Single Range Mode Configuration995.4.1.4. RNGE ( MODE ( DUAL: Dual Range Mode Configuration1005.4.1.5. RNGE ( MODE ( AUTO: Auto Range Mode Configuration1015.4.1.6. SETUP ( RNGE ( UNIT: Setting the Reporting Range Unit Type1025.5. SETUP ( PASS: PASSWORD PROTECTION1035.6. SETUP ( CLK: SETTING THE T400 ANALYZER’S INTERNAL TIME-OF-DAY CLOCK AND ADJUSTING SPEED1065.6.1.1. Setting the Internal Clock’s Time and Day1065.6.1.2. Adjusting the Internal Clock’s Speed1075.7. SETUP ( COMM: COMMUNICATIONS PORTS1085.7.1. ID (MACHINE IDENTIFICATION)1085.7.2. INET (ETHERNET)1085.7.3. COM1 AND COM 2 (MODE, BAUD RATE AND TEST PORT)1085.8. SETUP ( VARS: VARIABLES SETUP AND DEFINITION1095.9. SETUP ( DIAG :DIAGNOSTICS FUNCTIONS1115.10. USING THE MODEL T400 ANALYZER’S ANALOG I/O1135.10.1. ADJUSTING & CALIBRATING THE ANALOG OUTPUT SIGNALS1145.10.1.1. Calibration of the Analog Outputs1145.10.1.2. Enabling or Disabling the AutoCal for an Individual Analog Output1155.10.1.3. Automatic Group Calibration of the Analog Outputs1165.10.1.4. Manual Calibration of the Analog Outputs Configured for Voltage Ranges1185.10.1.5. Manual Adjustment of Current Loop Output Span and Offset1205.10.1.6. Analog Output Voltage / Current Range Selection1235.10.1.7. Turning an Analog Output Over-Range Feature ON/OFF1245.10.1.8. Adding a Recorder Offset to an Analog Output1255.10.1.9. Selecting a Test Channel Function for Output A41265.10.2. AIN CALIBRATION1285.10.3. CONFIGURING ANALOG INPUTS (OPTION)1296. COMMUNICATIONS SETUP AND OPERATION1316.1. DATA TERMINAL/COMMUNICATION EQUIPMENT (DTE DCE)1316.2. COMMUNICATION MODES, BAUD RATE AND PORT TESTING1316.2.1. COMMUNICATION MODES1326.2.2. COM PORT BAUD RATE1346.2.3. COM PORT TESTING1356.3. RS-2321366.4. RS-485 (OPTION)1366.5. ETHERNET1366.5.1. CONFIGURING ETHERNET COMMUNICATION MANUALLY (STATIC IP ADDRESS)1376.5.2. CONFIGURING ETHERNET COMMUNICATION WITH DYNAMIC HOST CONFIGURATION PROTOCOL (DHCP)1406.5.3. CHANGING THE ANALYZER’S HOSTNAME1436.6. USB PORT1446.7. COMMUNICATIONS PROTOCOLS1446.7.1. MODBUS1446.7.2. HESSEN1466.7.3. HESSEN COMM PORT CONFIGURATION1476.7.4. ACTIVATING HESSEN PROTOCOL1486.7.5. SELECTING A HESSEN PROTOCOL TYPE1496.7.6. SETTING THE HESSEN PROTOCOL RESPONSE MODE1506.7.7. HESSEN PROTOCOL GAS LIST ENTRIES1516.7.7.1. Gas List Entry Format and Definitions1516.7.7.2. Editing or Adding HESSEN Gas List Entries1526.7.7.3. Deleting HESSEN Gas List Entries1536.7.8. SETTING HESSEN PROTOCOL STATUS FLAGS1546.7.9. INSTRUMENT ID1557. DATA ACQUISITION SYSTEM (DAS) AND APICOM1577.1. DAS STATUS1587.2. DAS STRUCTURE1587.3. DAS CHANNELS1597.3.1. DAS DEFAULT CHANNELS1607.3.2. SETUP (DAS (VIEW: VIEWING DAS CHANNELS AND INDIVIDUAL RECORDS1627.4. SETUP (DAS (EDIT: ACCESSING THE DAS EDIT MODE1637.4.1. EDITING DAS DATA CHANNEL NAMES1647.4.2. EDITING DAS TRIGGERING EVENTS1657.4.2.1. EditiNg DAS Parameters1667.4.3. EDITING SAMPLE PERIOD AND REPORT PERIOD1687.4.4. REPORT PERIODS IN PROGRESS WHEN INSTRUMENT IS POWERED OFF1697.4.5. EDITING THE NUMBER OF RECORDS1697.4.6. RS-232 REPORT FUNCTION1717.4.7. ENABLING / DISABLING THE HOLDOFF FEATURE1727.4.8. THE COMPACT REPORT FEATURE1727.4.9. THE STARTING DATE FEATURE1737.5. DISABLING/ENABLING DATA CHANNELS1737.6. REMOTE DAS CONFIGURATION1747.7. DAS CONFIGURATION LIMITS1748. REMOTE OPERATION1758.1. COMPUTER MODE1758.1.1. REMOTE CONTROL VIA APICOM1758.2. INTERACTIVE MODE1768.2.1. REMOTE CONTROL VIA A TERMINAL EMULATION PROGRAM1768.2.1.1. Help Commands in Interactive Mode1768.2.1.2. Command Syntax1778.2.1.3. Data Types1778.2.1.4. Status Reporting1788.3. REMOTE ACCESS BY MODEM1798.4. PASSWORD SECURITY FOR SERIAL REMOTE COMMUNICATIONS1828.5. APICOM REMOTE CONTROL PROGRAM1829. T400 CALIBRATION PROCEDURES1859.1. BEFORE CALIBRATION1869.1.1. REQUIRED EQUIPMENT, SUPPLIES, AND EXPENDABLES1869.1.2. ZERO AIR AND SPAN GAS1869.2. BASIC MANUAL CALIBRATION CHECKS AND CALIBRATION OF THE T400 ANALYZER1879.2.1. SETUP FOR BASIC CALIBRATION CHECKS AND CALIBRATION OF THE T400 ANALYZER.1879.2.2. PERFORMING A BASIC MANUAL CALIBRATION CHECK1889.2.3. PERFORMING A BASIC MANUAL CALIBRATION1899.2.3.1. Setting the Expected O3 Span Gas Concentration1899.2.3.2. Zero/Span Point Calibration Procedure1909.2.4. MANUAL CALIBRATION CHECKS AND CALIBRATIONS USING AUTO RANGE OR DUAL RANGE MODES1919.3. MANUAL CALIBRATION CHECK AND CALIBRATION WITH VALVE OPTIONS INSTALLED1929.3.1. SETUP FOR CALIBRATION CHECKS AND CALIBRATION WITH VALVE OPTIONS INSTALLED.1929.3.2. MANUAL CALIBRATION CHECKS WITH VALVE OPTIONS INSTALLED1949.3.3. MANUAL CALIBRATION USING VALVE OPTIONS1959.3.3.1. Setting the Expected O3 Span Gas Concentration with the Z/S Option Installed1959.3.3.2. Zero/Span Point Calibration Procedure the Z/S Option Installed1969.3.3.3. Use of Zero/Span Valve with Remote Contact Closure1979.4. AUTOMATIC ZERO/SPAN CAL/CHECK (AUTOCAL)1979.4.1. SETUP ( ACAL: PROGRAMMING AND AUTO CAL1999.5. O3 PHOTOMETER ELECTRONIC CALIBRATION2019.5.1. PHOTOMETER DARK CALIBRATION2019.5.2. O3 PHOTOMETER GAS FLOW CALIBRATION2039.6. CALIBRATING THE IZS OPTION O3 GENERATOR20410. EPA PROTOCOL CALIBRATION20710.1.1. T400 CALIBRATION – GENERAL GUIDELINES20710.1.2. CALIBRATION EQUIPMENT, SUPPLIES, AND EXPENDABLES20810.1.3. CALIBRATION GAS AND ZERO AIR SOURCES20910.1.4. RECOMMENDED STANDARDS FOR ESTABLISHING TRACEABILITY20910.1.5. CALIBRATION FREQUENCY21010.1.6. DATA RECORDING DEVICE21110.1.7. RECORD KEEPING21110.2. LEVEL 1 CALIBRATIONS VERSUS LEVEL 2 CHECKS21210.3. MULTIPOINT CALIBRATION21310.3.1. GENERAL INFORMATION21310.3.2. MULTIPOINT CALIBRATION PROCEDURE21310.3.3. DYNAMIC MULTIPOINT CALIBRATION CHECK21410.3.4. LINEARITY TEST21510.3.5. O3 LOSS CORRECTION FACTOR21710.3.6. SPAN DRIFT CHECK21710.4. AUDITING PROCEDURES21710.4.1. DATA PROCESSING AUDIT21810.4.2. SYSTEM AUDIT21910.4.3. ASSESSMENT OF MONITORING DATA FOR PRECISION AND ACCURACY21910.5. SUMMARY OF QUALITY ASSURANCE CHECKS22010.6. REFERENCES22311. INSTRUMENT MAINTENANCE22711.1. MAINTENANCE SCHEDULE22711.2. PREDICTIVE DIAGNOSTICS23111.3. MAINTENANCE PROCEDURES23211.3.1. REPLACING THE SAMPLE PARTICULATE FILTER23211.3.2. REBUILDING THE SAMPLE PUMP23311.3.3. REPLACING THE IZS OPTION ZERO AIR SCRUBBER23311.3.4. IZS DESICCANT (OPTION 56)23411.3.5. PERFORMING LEAK CHECKS23411.3.5.1. Vacuum Leak Check and Pump Check23411.3.5.2. Pressure Leak Check23411.3.6. PERFORMING A SAMPLE FLOW CHECK23611.3.7. MAINTENANCE OF THE PHOTOMETER ABSORPTION TUBE23711.3.7.1. Cleaning or Replacing the Absorption Tube23711.3.7.2. UV Lamp Adjustment23811.3.7.3. UV Lamp Replacement24011.3.8. ADJUSTMENT OR REPLACEMENT OF OPTIONAL IZS OZONE GENERATOR UV LAMP24112. TROUBLESHOOTING & SERVICE24512.1. GENERAL TROUBLESHOOTING24512.1.1. FAULT DIAGNOSIS WITH WARNING MESSAGES24612.1.2. FAULT DIAGNOSIS WITH TEST FUNCTIONS25012.1.3. DIAG ( SIGNAL I/O: USING THE DIAGNOSTIC SIGNAL I/O FUNCTION25212.2. USING THE ANALOG OUTPUT TEST CHANNEL25412.3. USING THE INTERNAL ELECTRONIC STATUS LEDS25512.3.1. CPU STATUS INDICATOR25512.3.2. RELAY PCA STATUS LEDS25512.3.2.1. I2C Bus Watchdog Status LEDs25512.3.2.2. O3 Option Status LED s25612.4. GAS FLOW PROBLEMS25712.4.1. TYPICAL FLOW PROBLEMS25712.4.1.1. Flow is Zero25712.4.1.2. Low Flow25712.4.1.3. High Flow25812.4.1.4. Actual Flow Does Not Match Displayed Flow25812.4.1.5. Sample Pump25812.5. CALIBRATION PROBLEMS25812.5.1. MIS-CALIBRATED25812.5.2. NON-REPEATABLE ZERO AND SPAN25812.5.3. INABILITY TO SPAN – NO SPAN BUTTON (CALS)25912.5.4. INABILITY TO ZERO – NO ZERO BUTTON (CALZ)25912.6. OTHER PERFORMANCE PROBLEMS25912.6.1. TEMPERATURE PROBLEMS25912.6.1.1. Box Temperature25912.6.1.2. Sample Temperature26012.6.1.3. UV Lamp Temperature26012.6.1.4. IZS Ozone Generator Temperature (Optional)26012.7. SUBSYSTEM CHECKOUT26112.7.1. AC MAIN POWER26112.7.2. DC POWER SUPPLY26112.7.3. I2C BUS26212.7.4. TOUCHSCREEN INTERFACE26312.7.5. LCD DISPLAY MODULE26312.7.6. RELAY PCA26312.7.7. PHOTOMETER PRESSURE /FLOW SENSOR ASSEMBLY26412.7.8. MOTHERBOARD26512.7.8.1. Test Channel / Analog Outputs Voltage26512.7.8.2. A/D Functions26612.7.8.3. Status Outputs26612.7.8.4. Control Inputs26712.7.9. CPU26712.7.10. RS-232 COMMUNICATIONS26812.7.10.1. General RS-232 Troubleshooting26812.7.10.2. Troubleshooting Analyzer/Modem or Terminal Operation26812.8. TROUBLE SHOOTING THE PHOTOMETER26912.8.1. CHECKING MEASURE / REFERENCE VALVE26912.8.2. CHECKING THE PHOTOMETER UV LAMP POWER SUPPLY27012.9. TROUBLE SHOOTING THE IZS OPTIONS O3 GENERATOR27112.9.1. CHECKING THE O3 GENERATOR UV LAMP POWER SUPPLY27112.10. SERVICE PROCEDURES27112.10.1. REPAIRING SAMPLE FLOW CONTROL ASSEMBLY27112.10.2. REPLACING THE STANDARD REFERENCE O3 SCRUBBER27212.10.3. REPLACING THE IZS O3 SCRUBBER27312.10.4. METAL WOOL SCRUBBER OPTION27312.10.5. DISK-ON-MODULE REPLACEMENT PROCEDURE27312.11. FAQ’S27412.12. TECHNICAL ASSISTANCE27613. THEORY OF OPERATION27713.1. MEASUREMENT METHOD27713.1.1. CALCULATING O3 CONCENTRATION27713.1.2. THE PHOTOMETER UV ABSORPTION PATH27913.1.3. THE REFERENCE / MEASUREMENT CYCLE28013.1.4. INTERFERENT REJECTION28113.2. PNEUMATIC OPERATION28213.2.1. SAMPLE GAS AIR FLOW28213.2.2. FLOW RATE CONTROL28313.2.2.1. Critical Flow Orifice28313.2.3. PARTICULATE FILTER28413.2.4. PNEUMATIC SENSORS28413.2.4.1. Sample Pressure Sensor28413.2.4.2. Sample Flow Sensor28413.3. ELECTRONIC OPERATION28513.3.1. OVERVIEW28513.3.2. CPU28613.3.2.1. Disk-On-Module28713.3.2.2. Flash Chip28713.3.3. MOTHERBOARD28813.3.3.1. A to D Conversion28813.3.3.2. Sensor Inputs28813.3.3.3. Thermistor Interface28813.3.3.4. Analog Outputs28913.3.3.5. External Digital I/O28913.3.3.6. I2C Data Bus28913.3.3.7. Power Up Circuit29013.3.4. RELAY PCA29013.3.4.1. Status LEDs29213.3.4.2. Watchdog Circuitry29213.3.4.3. Valve Control29313.3.4.4. Heater Control29313.3.4.5. Thermocouple Inputs and Configuration Jumper (JP5)294POWER SUPPLY/CIRCUIT BREAKER29513.3.5.1. Power Switch/Circuit Breaker29613.3.6. AC POWER CONFIGURATION29713.3.6.1. AC Configuration – Internal Pump (JP7)29813.3.6.2. AC Configuration – Heaters for Option Packages (JP6)29913.3.7. PHOTOMETER LAYOUT AND OPERATION30013.3.7.1. Photometer Electronic Operation30113.3.7.2. O3 Photometer UV Lamp Power Supply30213.3.7.3. Photometer Temperature30313.3.7.4. Photometer Gas Pressure and Flow Rate30313.4. FRONT PANEL TOUCHSCREEN/DISPLAY INTERFACE30413.4.1. FRONT PANEL INTERFACE PCA30413.5. SOFTWARE OPERATION30513.5.1. ADAPTIVE FILTER30513.5.2. CALIBRATION - SLOPE AND OFFSET30614. A PRIMER ON ELECTRO-STATIC DISCHARGE30714.1. HOW STATIC CHARGES ARE CREATED30714.2. HOW ELECTRO-STATIC CHARGES CAUSE DAMAGE30814.3. COMMON MYTHS ABOUT ESD DAMAGE30914.4. BASIC PRINCIPLES OF STATIC CONTROL31014.4.1. GENERAL RULES31014.4.2. BASIC ANTI-ESD PROCEDURES FOR ANALYZER REPAIR AND MAINTENANCE31214.4.2.1. Working at the Instrument Rack31214.4.2.2. Working at an Anti-ESD Work Bench.31214.4.2.3. Transferring Components from Rack to Bench and Back31314.4.2.4. Opening Shipments from Teledyne API Customer Service31314.4.2.5. Packing Components for Return to Teledyne API Customer Service314サイズ: 8.1MBページ数: 396Language: Englishマニュアルを開く