 F33-3 Freestanding Gas Stove
DRAFT HOOD
The heater has a draft hood built into its back. It must not be altered 
or obstructed, and the unit must be installed so that the draft hood is 
in the same atmospheric pressure zone as the combustion air inlet 
to the burner.
FLUEING
This heater is a vented appliance and must be connected to a chim-
ney/fl ue in accordance with installation codes.
For your safety this heater is equipped  with a fl ue safety switch. This 
thermally actuated switch is located within the draft hood and will detect 
INSTALLATION
either a blocked chimney or backdraft condition where the chimney 
fl ow has reversed and will react by shutting off the gas supply.
Note: 
The spill switch is manually resettable and comes from 
the factory in the open position. Before trying to start 
up the unit, make sure the red button on the spill switch 
is pushed in.
FLUEING REQUIREMENTS 
100mm diameter fl ue is required in accordance with AS5601-2004, 
NZS 5261 or any relevant  local building codes.  For altitudes above 
610m. we recommend that a minimum fl ue height of 3.6m is used.
WIRING
CAUTION:   
Label all wires prior to disconnection 
when servicing controls. 
Wiring errors can cause improper and 
dangerous operation.
WARNING: Electrical Grounding 
Instructions
This appliance is equipped with a three 
pronged (grounding) plug for your 
protection against shock hazard and 
should be plugged directly into a prop-
erly grounded three-prong receptacle. 
Do not cut or remove the grounding 
prong from this plug.
No electrical power supply is required for the 
gas control to operate. However,  a 240V A.C. 
power supply is needed for the fan/blower 
operation.
Caution: Ensure that the wires do not 
touch any hot surfaces and are away 
from sharp edges.