Hitachi SJ300-037HFE 사용자 설명서

다운로드
페이지 289
SJ300 Inverter
Appendix B
B–13
Command – 06
The 06 command reads a single parameter 
value from the inverter, which is specified by 
the data field this read command.
The receive frame includes an ACK 
(acknowledge) character, followed by an
8-byte data field.
Use the codes in the table below to return parameters for H03 and H203 (motor capacity selec-
tion).
Element
Description
Size
Value
STX
Control code (STart of TeXt)
1 byte
STX (0x02)
Node
Node (station) address of inverter
2 bytes 01 to 32
Command
Transmission command
2 bytes 06
Data
Parameter specified to be read
4 bytes (see tables below)
BCC
Block check sum code
2 bytes Exclusive OR of Node, 
Command, and Data
[CR]
Control code (carriage return)
1 byte
[CR] (0x0D)
Element
Description
Size
Value
STX
Control code (STart of TeXt)
1 byte
STX (0x02)
Node
Node (station) address of inverter
2 bytes 01 to 32
ACK
Control code (ACKnowledge)
1 byte
ACK (0x06)
Data
Parameter value
8 bytes Value of parameter times ten, 
returned as ASCII char. code,
 except for H003 and H203 (see 
table below)
BCC
Block check sum code
2 bytes Exclusive OR of Node, 
Command, and Data
[CR]
Control code (carriage return)
1 byte
[CR] (0x0D)
Code Data
00
01
02
03
04
05
06
07
08
09
10
U.S. mode (B85=00, 02)
0.2 kW
0.4
0.75
1.5
2.,2
3.7
EU mode (B85=01)
0.2 kW
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
Code Data
11
12
13
14
15
16
17
18
19
20
21
U.S. mode (B85=00, 02)
5.5 kW
7.5
11
15
18.5
22
30
37
45
55
75
EU mode (B85=01)
5.5 kW
7.5
11
15
18.5
22
30
37
45
55
75
STX Node
Command
Data
BCC [CR]
Transmit frame format
STX Node
ACK
Data
BCC [CR]
Receive frame format