Data Communications Setup  
••••  65 
Troubleshooting 
This chapter is intended for maintenance personnel. 
Failure of the DNH to establish a link is the principle cause of most hub 
failures. Typical problems are: 
•  Configuration Conflict 
•  Link Signal Quality 
 
The DNH port green LED is off, or intermittently flashes between green 
and red. This can indicate a configuration conflict caused by a faulty ca-
ble or a wrong connection or improper configuration parameters. 
1.  Inspect all cable and connectors for damage.  
2.  Verify that the cable is connected to the correct Hub half and correct 
Port. 
3.  Verify that the Channel ‘A’ link is connected to the ‘A’ Hub half and 
that the Channel ‘B’ link is connected to the ‘B’ Hub half.  
4.  Verify that both Channels A & B use the same port number on their 
respective Hub half.  
5.  Display the Port Status screen by connecting a PC to the Configura-
tion Port, logging in, and then typing display links. Verify that all 
Ports are connected as expected; see example below. 
The following example shows that Port 1 on the B Hub is incorrectly con-
nected to Port 1 Channel A, on device 172.16.99.7. 
local> display links 
Port status for 172.16.99.3, B 
Port:    Medium:  Status:         "A" connected to:      "B" connected to: 
1        Copper   Validation                                         172.016.099.0071A 
2        Copper   Unconnected 
3        Copper   Unconnected 
4        Copper   Unconnected 
5        Copper   Unconnected 
6        Copper   Unconnected 
7        Copper   Unconnected 
8        Copper   Unconnected 
9        Copper   Unconnected 
Ethernet          Offline 
The Ethernet port is always shown as Offline on the ‘B’ Hub half because 
the Ethernet port is always disabled on the ‘B’ Hub. 
Description 
Configuration 
Conflicts 
Cabling errors: 
Example 
NOTE