BMI Technologies Inc. RFVI 사용자 설명서

다운로드
페이지 85
G FORCE PLUS RF Instruction Manual 
 
 
Apr/08
 78 
Doc #RF1 Rev.9 
Battery Low Fault Threshold (SGP) 
The Vehicle enters Battery Fault when a battery has a sustained 
level below this specific gravity point threshold.  The Vehicle 
Interface displays “BATTERY FAULT OVER/UNDER 
VOLT.”
 and the red Battery Fault LED illuminates.  Other 
interrupts and alarms will exhibit as programmed.  To begin 
clearing this condition, the Vehicle must be placed into 
Maintenance Lockout.  See “RECOMMENDED SETTINGS”. 
 
Authorization Groups 
 
Authorization Group settings apply to all Vehicles in an Authorization Group, and changes require all 
Vehicles in the Authorization Group to be reprogrammed with the Data Logger. 
 
General Tab 
 
Auth Group 
Enter a unique Authorization Group from 1 to 64. 
Description 
Enter an Authorization Group description. 
Diagnostic Delay (seconds) 
For the defined number of seconds, all electrical circuits are 
closed so a Vehicle can conduct its internal diagnostics 
without error.  The Vehicle Interface displays “VEH 
SYSTEM CHECK PLS WAIT..”
 after key-on.   
Preventative Maintenance Time 
Tracking Method 
Select one of two options to track time for scheduled 
Preventative Maintenance purposes: 
1) Login Time 
2) Motion Time 
 
Preventative Maintenance 
Interval/Frequency every (hours) 
This value is used to increment the current G FORCE Hour 
Meter to determine when the next scheduled Preventative 
Maintenance should be.   
Impact Automatic Reset (if checked) 
When this field is checked, the Vehicle Interface displays 
“OPERATOR LOGIN PRESENT CARD” after an Impact 
has been detected.   
Battery Monitoring (if checked) 
When this field is checked, the Vehicle battery is monitored.  
Additional settings are required for customization. 
Settings Tab 
 
Operator Login Lift Interrupt (if 
checked) 
The circuit wired to interrupt the Vehicle lift opens during 
Operator Login (lift interrupt created). 
Operator Login Secondary Alarm (if 
checked) 
The circuit wired to create a secondary alarm opens during 
Operator Login. 
Hot Card Lift Interrupt (if checked) 
The circuit wired to interrupt the Vehicle lift opens when a 
Hot Card is detected for Operator Login (lift interrupt 
created). 
Hot Card Secondary Alarm (if 
checked) 
The circuit wired to create a secondary alarm opens when a 
Hot Card state is detected for Operator Login). 
Maintenance Lockout Lift Interrupt 
(if checked) 
The circuit wired to interrupt the Vehicle lift opens when a 
Vehicle enters Maintenance Lockout (lift interrupt created).