Maintenance Lockout Secondary 
Alarm (if checked) 
The circuit wired to create a secondary alarm opens when a 
Vehicle enters Maintenance Lockout. 
Impact Lift Interrupt (if checked) 
The circuit wired to interrupt the Vehicle lift opens when an 
Impact is detected (lift interrupt created) 
Impact Secondary Alarm (if checked) 
The circuit wired to create a secondary alarm opens when an 
Impact is detected. 
Impact Delay (seconds) 
There is a delay for the defined number of seconds before the 
Lift Interrupt and Secondary Alarm circuits open after an 
Impact is detected. 
Battery OK To Charge Threshold 
(SGP) 
The Vehicle enters OK To Charge when a battery discharges 
to a level below this specific gravity point threshold for a 
sustained period of time (see Battery OK To Charge Timer 
below).  The Vehicle Interface displays “BATTERY OK TO 
CHARGE”
 and the Battery Charge LED illuminates as 
amber.  Other alarms will exhibit as programmed.   
Set the upper limit of the OK To Charge battery range in 
specific gravity points according to your company’s battery 
charging policy.  See “RECOMMENDED SETTINGS”. 
Battery OK To Charge Timer 
(minutes) 
The Vehicle enters OK To Charge when a battery discharges 
to a level below the Battery OK To Charge Threshold for this 
period of time.  The Vehicle Interface displays “BATTERY 
OK TO CHARGE”
 and the Battery Charge LED illuminates 
as amber.  Other alarms will exhibit as programmed.   
Set this value to reflect your company’s battery charging 
policy.  See “RECOMMENDED SETTINGS”. 
Battery Must Charge Threshold 
(SGP) 
The Vehicle enters Must Charge when a battery discharges to 
a level below this specific gravity point threshold for a 
sustained period of time (see Battery Must Charge Timer 
below).  The Vehicle Interface displays “BATTERY MUST 
CHARGE!”
 and the Battery Charge LED flashes red.  Other 
interrupts and alarms will exhibit as programmed.   
Set the upper limit of the Must Charge battery range in 
specific gravity points according to your company’s battery 
charging policy.  See “RECOMMENDED SETTINGS”. 
Battery Must Charge Timer (minutes) 
The Vehicle enters Must Charge when a battery discharges to 
a level below the Battery Must Charge Threshold for this 
period of time.  The Vehicle Interface displays “BATTERY 
MUST CHARGE!”
 and the Battery Charge LED flashes red.  
Other interrupts and alarms will exhibit as programmed.   
Set this value to reflect your company’s battery charging 
policy.  See “RECOMMENDED SETTINGS”. 
Battery Must Charge Lift Interrupt (if 
checked) 
The circuit wired to interrupt the Vehicle lift opens when 
Battery Must Charge is detected (lift interrupt created). 