Option
Function
Error
The status flag “Error” lights up and the motor will stopped if an error has occurred.
The TMC603 has three different sources for signaling an error:
The TMC603 has three different sources for signaling an error:
1. Undervoltage of the low side supply
2. Undervoltage of the charge pump
3. Short to GND detector
In addition the status flag “Error” lights up if you try to ramp up the motor with sine
startup and no initialization has been done.
startup and no initialization has been done.
Overload
The status flag “Overload” lights up if a current overload is detected. In this case
the PWM duty cycle will be decreased. You can define the current limiting by
setting the parameter “Maximum current”.
the PWM duty cycle will be decreased. You can define the current limiting by
setting the parameter “Maximum current”.
Current Control
Here you can configure the current controller. Please take into account the
manufacturer’s data of the used BLDC motor.
manufacturer’s data of the used BLDC motor.
Current Ref.
The current reference value defines the maximum current value for startup.
Current Time
The parameter “Current Time” is the regulation time of the current controller.
Current
Control Kp
Control Kp
The parameter “Current Control Kp” is the proportional gain (Kp) of the controller.
Speed Control
In this field you can modify the speed control parameters.
Speed Ref.
The speed reference value defines the actual motor speed.
Speed Ctl.
Time
Time
The speed control time is given in milliseconds (ms). In this time the PWM duty
cycle counts up or down by a value of 1/16 %.
cycle counts up or down by a value of 1/16 %.
Duty Cycle
Ref.
Ref.
If the speed control is disabled, the duty cycle reference value defines the actual
PWM duty cycle.
PWM duty cycle.
Enable speed
control
control
If this option is selected the speed control is enabled. You can disable the speed
control by deactivating this option. In this case you can enter the PWM duty cycle
(Duty cycle ref.) by pressing the “Set” button. If you disable the speed control, be
sure that the “Duty Cycle Ref.” is unequal to zero. Otherwise the motor will stop.
Please note if the speed control is disabled, the motor will start without ramp up.
control by deactivating this option. In this case you can enter the PWM duty cycle
(Duty cycle ref.) by pressing the “Set” button. If you disable the speed control, be
sure that the “Duty Cycle Ref.” is unequal to zero. Otherwise the motor will stop.
Please note if the speed control is disabled, the motor will start without ramp up.
Current
Measurement
Measurement
These display fields show the actual currents of the 3 phase BLDC motor and the
overall current. The status flags display the actual amplification of the internal
amplifier of TMC603.
overall current. The status flags display the actual amplification of the internal
amplifier of TMC603.
I1
This display field shows the actual current (I
1RMS
) of the motor phase U.
I2
This display field shows the actual current (I
2RMS
) of the motor phase V.
I3
This display field shows the actual current (I
3RMS
) of the motor phase W.
I
This display field shows the actual overall current (I
RMS
) of the motor.
Low
amplification
amplification
The status flag “Low amplification (4.5)” lights up if the actual amplification of the
internal amplifier of TMC603 is set to low.
internal amplifier of TMC603 is set to low.
High
amplification
amplification
The status flag “Low amplification (18.4)” lights up if the actual amplification of the
internal amplifier of TMC603 is set to high.
internal amplifier of TMC603 is set to high.
Get/Set buttons
By pressing these buttons the parameters will received and transmitted
respectively.
respectively.
Get
All parameters may be read by pressing the res
pective “Get” button.
Set
Press the “Set” button to send the parameters to the evaluation board.
Table 6: Several parts of PC software (continued)