4  Quick Start 
4.1  Connecting the motor 
For a first quick start, plug the jumpers on the evaluation board like shown in Figure 2. Please check if 
the jumpers X212, X213 and X214 are plugged. Connect a three phase BLDC motor to the connector 
X301 (motor coil output). The pins are marked by “U”, “V” and “W”. Please note that the BLDC motors 
may only be connected to or disconnected from the evaluation board while the board is disconnected 
from power supply, as otherwise the evaluation board could get damaged! 
 
 
Figure 2: Default settings of jumpers for quick start 
 
4.2  Connecting the RS232 interface and power supply 
Connect  the  RS232  interface  (X116)  to  the  PC  by  using  a  null  modem  cable.  The  baud  rate  is 
automatically  set  to  115200  baud  by  the  PC  software.  Now,  connect  the  power  supply  between  12V 
and 48V and at least 1A to the connector X201 (power supply). The positive 
terminal is marked “12V-
48V”. The green “POWER ON” LED will light up after attaching the power supply. 
 
 