4 Quick Start
4.1 Connecting the motor
For a first quick start, plug the jumpers on the evaluation board like shown in Figure 2. Please check if
the jumpers X212, X213 and X214 are plugged. Connect a three phase BLDC motor to the connector
X301 (motor coil output). The pins are marked by “U”, “V” and “W”. Please note that the BLDC motors
may only be connected to or disconnected from the evaluation board while the board is disconnected
from power supply, as otherwise the evaluation board could get damaged!
the jumpers X212, X213 and X214 are plugged. Connect a three phase BLDC motor to the connector
X301 (motor coil output). The pins are marked by “U”, “V” and “W”. Please note that the BLDC motors
may only be connected to or disconnected from the evaluation board while the board is disconnected
from power supply, as otherwise the evaluation board could get damaged!
Figure 2: Default settings of jumpers for quick start
4.2 Connecting the RS232 interface and power supply
Connect the RS232 interface (X116) to the PC by using a null modem cable. The baud rate is
automatically set to 115200 baud by the PC software. Now, connect the power supply between 12V
and 48V and at least 1A to the connector X201 (power supply). The positive
automatically set to 115200 baud by the PC software. Now, connect the power supply between 12V
and 48V and at least 1A to the connector X201 (power supply). The positive
terminal is marked “12V-
48V”. The green “POWER ON” LED will light up after attaching the power supply.
Figure 3: The TMC603 Evaluation Software