STEP 5 – Program the Communicator 
You must use the 7720P Programming tool to program the IPGSM-4GC.  
When using the 7720P Programming tool, the values given below are for most installations.  Press the [#] key to 
accept the displayed default value (xxx) or enter the new value and press the [#] key for the next prompt.  Use the 
[
Space
] key to scroll through a list of options. 
 
 
 
1.    (no display) 
 
Connect the 7720P.  (You can use the [Shift + A] key to check the software 
revision.) 
 
 
 
2. 
7720P PROGRAMMER 
 
Press [#]. 
 
 
 
3. 
Strt Prog Mode? Y/N 
 
Press [Shift] then [Y], then [#]. 
 
 
 
4. 
Program Device?  Y/N 
 
Press [Shift] then [Y], then [#].  
 
 
 
5. 
Com Path Choice  (IP&GSM) 
 
Press [Space] to scroll choices; IP&GSM, IP, or GSM.  (When IP, or GSM, or 
IP&GSM is chosen, the IPGSM-4GC functions as an active communication 
system.)  At choice, press [#]. 
 
 
 
6. 
Primary City ID  (??) 
 
Enter number 01-99, then press [#]. 
 
 
 
7. 
Primary CS ID  (??)  
 
Enter number 01-FE, then press [#]. 
 
 
 
8. 
Primary Sub ID  (????)  
 
Enter number 0001-9999, then press [#].  
 
 
 
 
Note: If a Com Path Choice of IP&GSM or IP was selected, prompt 9 will appear. 
 
 
 
9. 
Use DHCP? Y/N (Y) 
 
If your router is configured for DHCP, press [Shift] then [Y], then press [#]. 
 
 
 
 
Note: If DHCP is not selected (your router is set for a static IP), prompts 10 through 13 will appear.  Use 
the [Space] key to advance to the next address part.  
 
 
 
10.  NIC IP Address:  
255.255.255.255 
Enter choice, then press [#].  Follow the prompts. 
 
 
 
11.  Subnet Mask:  
255.255.255.255 
Enter choice, then press [#].  Follow the prompts. 
 
 
 
12.  Gateway IP Address: 
255.255.255.255 
Enter choice, then press [#].  Follow the prompts. 
 
 
 
13.  DNS Serv IP Addr: 
255.255.255.255 
Enter choice, then press [#].  Follow the prompts. 
 
 
 
14.  Review? Y/N 
 
Enter choice, then press [#].  Follow the prompts. 
 
 
 
15.  Create Password?  Y/N 
 
Enter choice, then press [#].  Follow the prompts. 
 
 
 
16.  Exit Prog Mode? Y/N 
 
Press [Shift] then [Y], then press [#]. 
 
 
 
17.  DONE 
 
 
 
 
 
 
Notes: 
 
If an error in programming occurs, set the factory defaults (see next topic) and reprogram. 
 
 
The IP Fault Time, and the GSM Fault Time are each fixed at 1 minute and are not programmable.