Toshiba E6581830 Manual Do Utilizador

Página de 51
 
E658130 
- 48 - 
7.3. 
How to check the error using the LEDs 
The following example explains the causes of fault which may be judged from the LED 
status of the CC-Link unit (CCL003Z) of the inverter.
 
 
1. When One Inverter Is Connected 
 
The following example indicates the causes of faults which may be judged from the LED status 
of the CC-Link unit (CCL003Z) of the inverter under the condition that the SW, M/S and PRM 
LEDs of the master unit are off (the master unit setting is correct) in the system configuration 
where one inverter is connected. 
 
 
 
 
PS: 
Power 
supply 
LED Status 
L.RUN SD  RD L.ERR 
Cause Corrective 
Action 
Normal communication is   
made but CRC error has   
occurred due to noise. 
Check that the communication cable is   
connected to SLD.   
Also wire it as far away as possible from 
the power lines.(200mm or more) 
 
 
 
 
Baud rate or station number 
was changed during   
operation. 
After correcting the baud rate and/ir 
station number setting, switch power on 
again. 
 
 
 
 
Normal communication 
 
 
 
 
Cannot answer due to CRC   
error of receive data. 
Check that the communication cable is   
connected to SLD.   
Also wire it as far away as possible from 
the power lines.(200mm or more) 
 
 
 
 
Data sent to the host station 
does not reach destination. 
Check the network transmission setting   
and the sequence program on the PLC   
side. 
 
 
 
 
Hardware fault 
(There is a possibility of the   
instability of the   
communication by the   
disconnection.) 
Check for contact fault, break in the cable, 
etc. 
 
 
 
 
Polling response is made but 
refresh receive is in CRC   
error. 
Check that the communication cable is   
connected to SLD.   
Also wire it as far away as possible from 
the power lines.(200mm or more) 
 
 
 
 
Data sent to the host station 
is in CRC error. 
Check that the communication cable is   
connected to SLD.   
Also wire it as far away as possible from 
the power lines.(200mm or more) 
 
 
 
 
There is no data sent to the 
host station, or data sent to 
the host station cannot be 
received due to noise. 
Check that the communication cable is   
connected to SLD.   
Also wire it as far away as possible from 
the power lines.(200mm or more) 
Cannot receive data due to   
break in the cable, etc. 
Check for contact fault, break in the cable, 
etc. 
 
 
 
 
WDT error occurrence   
(hardware fault), power off,   
power supply failure 
Check that CCL003Z is fitted properly. 
:
On, 
○:
OFF,  ◎:
Flicker, 
:
 Any of on, flicker or off.
 
                       Master
          CPU        Unit
 
Station
inverter