8. The appliance must be isolated from the gas supply piping system by closing its individual 
manual  shut-off  valve  during  any  pressure  testing  of  the  gas  supply  piping  system  at  test 
pressures equal to or less then ½ psi (3.45 kPa).
9. This appliance must be installed under a ventilation hood.
10. Do not obstruct the flow of combustion and ventilation air.
11. The area around this and any other gas appliance must always be kept free and clear from 
combustibles.
RETAIN THIS MANUAL FOR FUTURE REFERENCE.
B. UNPACKING INSTRUCTIONS: 
Carefully unpack the open burner range and inspect immediately for shipping damages. Your open   
burner range was shipped in a carton designed to give maximum protection in normal handling. It 
was thoroughly inspected before leaving the factory and the carrier accepted and signed for it. File 
any claims for shipping damage or irregularities with the carrier.
C. GAS CONNECTIONS
 
STANDING 
PILOT
A separate gas shut off valve (supplied with 
unit) must be installed in the gas line ahead of 
the  unit,  as  required  by  codes  (see  Fig. A). 
Gas supply line must be ¾” or larger. If flexible 
semi  rigid  connections  are  used,  the  inside 
diameter  must  be  the  equivalent  of  ¾”  iron 
pipe or larger. All connections of the flexible 
and semi rigid type must be AGA listed and 
comply with applicable ANSI standards. Make 
sure gas piping is clean and free of dirt, piping 
compound  and  obstruction.  To  insure 
maximum operating efficiency, this appliance 
must be connected with a Gas Supply Line of 
solid pipe or with a Commercial Type Flexible 
Connector with I.D. (inside diameter) equal or 
larger  than  the  gas  pipe  inlet  on  this 
appliance. 
CAUTION: BEFORE LIGHTING, CHECK ALL JOINTS IN THE GAS SUPPLY LINE FOR LEAKS. USE 
SOAP AND WATER SOLUTION. DO NOT USE OPEN FLAME. 
If the gas connections are leak-free, the unit is ready to use. Follow the lighting instructions.
PRESSURE REGULATOR
MAIN SHUT-OFF VALVE
2. LIGHTING INSTRUCTIONS
A. LIGHTING INSTRUCTIONS 
 
     1. Turn off all gas valves and main Shut-off valve and wait 5 minutes.
2. Turn the main gas valve to ON position and light standing pilots adjacent to each main 
burner. (FIG. A & B)
3. Repeat the above step for all standing pilots. There should be slight yellow tip on the pilot flame. 
Make sure all the pilots are lit. 
4. Turn the main burner valve to the ON position.
5. To relight follow steps 1-4.
B. SHUTDOWN INSTRUCTIONS
For complete shut down turn all the main burner valves and main gas valve to OFF position.
Pilot should be approximately ½”- ¾” in height.   Adjust as required 