3. MAINTENANCE INSTRUCTIONS
A. CLEANING INSTRUCTIONS
Clean the unit regularly after use. Burner ports and burner rest should be thoroughly cleaned. Top 
grates are easily removable. After cleaning rinse with clean water and dry with a dry cloth. 
Heavy sputtering or spills may require cleaning with a mild oven cleaner. 
Use mild soap or detergent to clean chassis and stainless steel parts.
To service burners or pilots TURN OFF GAS SUPPLY and remove top grates.
To provide proper operation and insure the safety of the user, this equipment must be maintained 
and serviced by a trained maintenance person or an authorized service agency at regular intervals. 
1. Burner ports must be thoroughly cleaned. Venturi must be free from grease and lint. 
2. All places where oil, grease or food can accumulate must be kept clean all the time.
3. Pilot light must be kept clean and adjusted at the proper flame height to assure constant ignition and 
to prevent fire flash-outs caused by delayed ignition.
4. Carelessness, abusive handling, or altering equipment can shorten the life of the equipment and 
jeopardize the limited warranty offered by Baker's Pride.
If you have any questions concerning the installation, operation, maintenance or service of this 
product please contact: Technical Service Department at (800) 431-2745 US & Canada
!
!
!
!
B. MAINTENANCE INSTRUCTIONS
Burners & pilots will 
not turn on
Burners produce 
excessive carbon 
deposits
Pilot will not remain lit.
Burners don't seem 
hot enough
Main gas supply to range is not 
turned on.
Incorrect gas type.
Incorrect gas supply pressure.
Incorrect orifices.
Primary air not adjusted properly.
Pilot flame adjusted incorrectly.
Draft condition.
Orifices may be dirty/clogged.
Low gas pressure.
Improper ventilation system.
Turn on main gas supply.
Supply correct type gas.
Call local gas supplier.
Call Bakers Pride authorized service center.
Adjust air shutter.
Adjust pilot flame.
Remove draft.
When unit cools, check & clean orifices.
Increase gas pressure to 3.5" W.C. (Nat) or 
10" W.C. (L.P.)
Call an HVAC specialist.