Cisco Cisco Unified Contact Center Enterprise 9.0(1)

Página de 254
Serviceability Best Practices Guide for Unified ICM/Unified CCE & Unified CCH 
©2012 Cisco Systems, Inc. 
 
71  
Object Name 
Description 
ID uniquely identifies the session layer addresses of an 
application functional component.  A single component may 
have multiple DMP IDs because a functional component 
communicates with other functional components (or its duplex 
pair) via multiple physical network interfaces and maintain 
multiple DMP session connections on each interface.  Should a 
communications failure occur, the event DMP ID identifies the 
physical and logical address that the error occurred. 
cccaEventSeverity 
The severity level of this notification.  The severity levels are: 
'informational' (1):  The notification contains important health 
or operational state information that is valuable to an 
administrator; however, the event itself does not indicate a 
failure or impairment condition. 
'warning' (2):  The notification contains serious health or 
operational state information that could be a precursor to 
system impairment or eventual failure. 
'error' (3):  The notification contains critical health or 
operational state information and indicates that the system has 
experienced an impairment and/or a functional failure. 
cccaEventTimestamp 
The date and time that the notification was generated on the 
originating node. 
cccaEventText 
The full text of the notification.  This text includes a 
description of the event that was generated, component state 
information, and potentially a brief description of 
administrative action that may be necessary to correct the 
condition that caused the event to occur. 
4.2 
 Dual State Objects 
Most objects are defined as dual state; they have either a raise or clear state. The raise state indicates 
that there is a problem or fault associated with the object. The clear state indicates the object is 
operating normally. 
A dual state Unified ICM/Unified CCE SNMP notification contains a raise(4) or clear(0) value in the 
cccaEventState field. In some cases, multiple raise notifications can correlate to the same object. For 
example, an object can go offline for a variety of reasons: process termination, network failure, 
software fault, and so on. The SNMP notification cccaEventComponentId field specifies a unique 
identifier that you can use to correlate common raise and clear notifications to a single managed 
object. 
The following example shows a pair of raise and clear notifications with the same 
cccaEventComponentId.  
Note: The first notification has a raise state; the notification that follows has a clear state. 
 
snmpTrapOID.0 = cccaIcmEvent 
cccaEventComponentId = 4_1_CC-RGR1A_ICM\acme\RouterA 
cccaEventState = raise(4 
cccaEventMessageId = 2701295877 
cccaEventOriginatingNode = CC-RGR1A\acme 
cccaEventOriginatingNodeType = router(1)