Puls ML15.241 Power Supply Guia De Especificação

Página de 21
 
 
ML15.241
 
 
MiniLine 
 
24V,
 
0.63A,
 
S
INGLE 
P
HASE 
I
NPUT
 
 
 
6.  O
UTPUT
 
 
Output voltage 
nom. 
24V 
 
Adjustment range 
min. 
24-28V 
guaranteed 
 
max. 
30V 
at clockwise end position of potentiometer 
Factory setting 
 
24.5V  
 ±0.2%, at full load, cold unit 
Line regulation 
max. 
10mV 
85-264Vac 
Load regulation 
max. 
100mV 
static value, 0A Æ 0.63A 
Ripple and noise voltage 
max. 
50mVpp 
20Hz to 20MHz, 50Ohm 
Output capacitance 
typ. 
900μF 
 
Output current  
nom. 
0.63A 
at 24V, see Fig. 6-1
 
nom. 
0.54A 
at 28V, see Fig. 6-1
Output power 
nom. 
15W 
 
Short-circuit current 
min. 
hiccup mode, see Fig. 6-2
hiccup 
 
 
Fig. 6-1   Output voltage vs. output current, 
typ. 
 
Fig. 6-2   Hiccup mode; output current at 
shorted output, 230Vac, typ. 
 
Output Voltage
0
0
4
8
12
28V
16
20
24
6/21
2A
1.0
0.6
0.2
1.4
0.8
0.4
1.2
1.6 1.8
Adjustment
Range
Output Current
Continuous
Hiccup Mode
 
 
Output
Current
0
2A
100ms
t
250ms
250ms
 
 
 
Peak current capability (up to several milliseconds) 
The power supply can deliver a peak current which is higher than the specified short term current. This helps to start 
current demanding loads or to safely operate subsequent circuit breakers. 
The extra current is supplied by the output capacitors inside the power supply. During this event, the capacitors will be 
discharged and causes a voltage dip on the output. Detailed curves can be found in chapter 22.1
Peak current voltage dips  
typ. 
from 24V to 15.5V 
at 1.3A for 50ms, resistive load 
 
typ. 
from 24V to 17.5V 
at 3.15A for 2ms, resistive load 
 
typ. 
from 24V to 11.5V 
at 3.15A for 5ms, resistive load 
 
Oct. 2009 / Rev. 1.2  DS-ML15.241-EN 
All parameters are specified at 24V, 0.63A, 230Vac input, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. 
www.pulspower.com   Phone +49 89 9278 0    Germany