Puls ML15.121 Power Supply Guia De Especificação
ML15.121
MiniLine-2
12V,
1.3A,
S
INGLE
P
HASE
I
NPUT
3. AC-I
NPUT
AC input
nom.
AC 100-240V
-15% / +10%, TN/TT/IT-mains
AC input range
85-264Vac continuous
operation
264–300Vac
<
0.5s
Allowed voltage L or N to earth
max.
300Vac
Input frequency
nom.
50–60Hz
±6%
Turn-on voltage
typ.
59Vac
steady-state value, see Fig. 3-1
Shut-down voltage
typ.
54Vac
steady-state value, see Fig. 3-1
AC 100V
AC 120V
AC 230V
Input current (rms)
typ.
0.34A
0.28A
0.17A
at 12V, 1.3A see Fig. 3-3
Power factor *)
typ.
0.52
0.51
0.44
at 12V, 1.3A see Fig. 3-4
Crest factor **)
typ.
3.45
3.53
3.94
at 12V, 1.3A
Start-up delay
typ.
780ms
780ms
780ms
see Fig. 5 2
Rise time
typ.
12ms
12ms
12ms
at 12V, 1.3A, see Fig. 3-2
Turn-on overshoot
max.
100mV 100mV 100mV
*)
The power factor is the ratio of the true (or real) power to the apparent power in an AC circuit.
**) The crest factor is the mathematical ratio of the peak value to RMS value of the input current waveform.
Fig. 3-1 Input voltage range
Fig. 3-2 Turn-on behavior, definitions
Turn-on
85V
Rated
input range
max.
500ms
V
IN
P
OUT
54V
300Vac
264V
Shut
-down
59V
Start-up
delay
Rise
Time
Overshoot
- 5%
Output
Voltage
Voltage
Intput
Voltage
Voltage
Fig. 3-3 Input current vs. output load at 12V
Fig. 3-4 Power factor vs. output load
1.4A
0.2
0.4
0.8
0
0
0.10
0.4A
Input Current, typ.
1.0
0.20
0.6
1.2
0.25
0.15
0.05
0.30
0.35
b
c
a
a) 100Vac
b) 120Vac
c) 230Vac
b) 120Vac
c) 230Vac
Output Current
1.4A
0.2
0.4
0.6
1.0
0.30
0.35
0.40
0.45
0.50
0.55
Power Factor, typ.
a) 100Vac
b) 120Vac
c) 230Vac
b) 120Vac
c) 230Vac
b
c
a
0.8
1.2
Output Current
Mar. 2013 / Rev. 2.1 DS-ML15.121-EN
All parameters are specified at 12V, 1.3A, 230Vac input, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
All parameters are specified at 12V, 1.3A, 230Vac input, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany