Adtran TRC4106 Manual Do Utilizador

Página de 68
TRACER 4206 System Manual
Section 5, User Interface Guide
612804206L1-1B
© 2002 ADTRAN, Inc.
61
>T1D P
ERFORMANCE
 H
ISTORY
Figure 23 shows the T1D Performance History menu page. The T1D Performance History menu page 
displays detailed error statistics for the T1D link (from both the local and remote TRACER 4106/4206 
units) in 15 minute increments. 
Figure 23.  T1D Performance History
T1D performance data is presented as Errored Seconds (ES) and Severely Errored Seconds (SES) on the 
T1D link. The following events qualify as an ES–AIS, LOS or LOF Alarm Second, a single BPV or 
excessive zero event, or a single parity bit. An SES is caused by an AIS, LOS or LOF Alarm Second, or 
excessive Bipolar Violations (BPVs) or framed Parity Bit errors causing a line Bit Error Rate (BER) of 
10
-6
.
The error count for the most recent 24 hours are recorded and displayed on the right side of the page.  The 
left side of the page displays the 24 hour totals for the most recent 7 days.
Press <N> to view the next 8 hours worth of 15 minute totals and <P> to view the 
previous 8 hours.
Press <8> from any menu in the TRACER 4106/4206 VT100 menu structure to access the 
T1D Link Performance History page.