Adtran TRC4106 Manual Do Utilizador

Página de 68
TRACER 4206 System Manual
Section 5, User Interface Guide
612804206L1-1B
© 2002 ADTRAN, Inc.
59
>T1D S
TATUS
/C
ONFIGURATION
/L
OOPBACK
Figure 20 shows the T1D Status/Configuration/Loopback menu page. Real-time graphical representation 
for the T1D link (using data from both the local and remote TRACER 4106/4206 units) is displayed on this 
page. T1D operational configuration parameters and testing functions are configured from this menu.
Figure 20.  T1D Status/Configuration/Loopback
>T1D S
TATUS
/C
ONFIGURATION
/L
OOPBACK
 > T1D I
NTERFACE
 A
LARMS
Displays and active alarms on the T1D link reported from both the local and remote TRACER 4106/4206 
units. These alarms include Red, Blue, Yellow, AIS, and bipolar violations (BPV). See Table 1 on page 
50, fo
r more information on these alarms.
>T1D S
TATUS
/C
ONFIGURATION
/L
OOPBACK
 > T1D L
INE
 B
UILD
 O
UT
Configures the T1D for the appropriate line buildout, based on the distance to the T1D equipment.  
>T1D S
TATUS
/C
ONFIGURATION
/L
OOPBACK
 > A
LARM
 R
EPORTING
Determines whether the TRACER 4106/4206 unit will report active alarms.  If 
D
ISABLED
, no alarms will 
be displayed on this menu page.  The Alarm Reporting parameter is independently configured for local and 
remote TRACER 4106/4206 units. When 
D
ISABLED
, the front panel LED alarms will also be disabled (off).
Press <7> from any menu in the TRACER 4106/4206 VT100 menu structure to access the 
T1D Status/Configuration/Loopback menu page.