ADC Telecommunications Inc. IRP1901A Manual Do Utilizador
Page 30
InterReach picoBTS Installation Guide
© 2008, ADC Telecommunications, Inc.
ADCP-77-061 • Issue A • 08/2008 • Chapter 3 - Commissioning and Configuration
6
shows the IP address parameters which must be modified to add your picoBTS
to your Ethernet network.
-
XXX.XXX.XXX.XXX
is the IP address. Replace it with the site-specific Ethernet IP
address for your network. The IP address is followed by ‘
:fffff000
’ which is the
subnet mask as a hexadecimal value. To modify the subnet mask of the processor
card, determine the proper hexadecimal value and enter following the colon. For
example to use a subnet of 255.255.255.0, you would follow the IP address with
‘:ffffff00’. The value displayed in the example ‘
card, determine the proper hexadecimal value and enter following the colon. For
example to use a subnet of 255.255.255.0, you would follow the IP address with
‘:ffffff00’. The value displayed in the example ‘
:fffff000
’ is equal to
255.255.240.0.
-
YYY.YYY.YYY.YYY
is the gateway router IP address. Enter the IP address of the
gateway router.
-
TARGET NAME sets the IP name. The default is “iwbox”. The TARGET NAME
parameter sets the IP name. The default is “iwbox”. You should enter a different name
for each system.
parameter sets the IP name. The default is “iwbox”. You should enter a different name
for each system.
7
Ensure that all other boot parameters are configured exactly as shown in the previous
figures.
figures.
8
If you have changed anything, for the new parameters to take effect, reboot the chassis by
pressing the key combination
pressing the key combination
[CTRL][x].
If you do not receive a prompt after reboot,
press
[ENTER]
to display the
HD:iwbox->
prompt.
9
Connect an Ethernet RJ-45 patch cable to the WAN port on the front of hte chassis.
10 Notify the OMC operator that the picoBTS is connected to the Ethernet, and give the
OMC operator the IP address and IP Name.
Note:
Use the IP name and IP address you received from your network administrator.
Caution:
You should ONLY change the
inet on ethernet, target name and gateway
inet parameters. All other parameters should NOT be modified.
Caution:
The OMC operator MUST have the correct
picoBTS
IP address, or the OMC will not be
able to communicate with the BS Plus.