Badger Meter Inc 2014GWGAL Manual Do Utilizador

Página de 24
Installation Manual
Figure 13:   Stripped cable wires
3 .  Shorten the foil shield flush with the outer jacket .
4 .  Strip the ends of the six (6) colored wires to a length of 1/8 inch . Twist the conductors on each wire .
5 .  Shorten the drain/bare wire (no insulation) to 11/16 inch .
6 .  Loosen each screw (about 2…3 turns) on the female insert and attach the wires to the insert using the chart below . 
Retighten each screw after the wire has been connected .
Function
Wire
Female insert connector
Female Insert Diagram - Top View
Female Insert Photo - Top View
RS232
White
4
V DC–
Drain
8 (center)
V DC–
Black
3
V DC+
Blue
7
V DC+
Red 
1
RS232
Green
5
V DC–
Brown
2
Not used
Not 
used
6
* Used with the serial programming harness (  66529-002)
**For use with shielded cable only
7 .  Assemble the insert by aligning the female insert tab slot with the notch in the coupling sleeve .
Figure 14:   Slot alignment
Insert Tab Slot
Coupling Sleeve  
Insert Notch
Slot
Brown
Red
Black
Blue
White
Not 
Used
Green
Drain
Page 15 