Tyco Safety Products/Sensormatic AMB9020 Manual Do Utilizador

Página de 12
Preliminary 2003-11-21 
DUAL ANTENNA SCANMAX PRO DEACTIVATOR CONTROLLER 
8200-0365-01, REV. 1A 
INSTALLATION AND SERVICE GUIDE 
8 of 12
 
Advanced Setup and  
Adapter Configuration 
Note: Be sure to adjust the correct antenna 
settings as indicated on the title bar of the 
configurator screen. 
Note: If the antenna has optional extension cable 
PN XXXX, you MUST select Extension Cable in 
the Antenna Setup for the unit to function properly. 
1.  Plug your laptop programming cable into the 
POS 1/SERV port of the controller. 
2.  Click the desktop icon to start the configurator 
software. The Setup Screen appears. For 
control definitions, see the Software 
Configurator Guide
3.  Verify settings correspond to the antennas 
used as follows. Do not change settings yet. 
Default Settings 
Antenna Tx 
Power Threshold 
LP Pro Pad 
Med 
8 (+1) inches 
20 (+2.5) cm 
PowerPad 
Pro 
Med 
7 (+1.5) inches 
17.5 (+3.75) cm 
SlimPad Pro 
Med 
6 (+1.5) inches 
15 (+3.75) cm 
IP Pro 
Med 
6 (+1.5) inches 
15 (+3.75) cm 
CompactPad 
Pro 
Med 
6 (+1) inches 
15 (+2.5) cm 
ScanMax IS* 
Med 
5 (+1) inches 
12.7 (+2.5) cm 
ScanMax HS 
Med 
5 (+1) inches 
12.7 (+2.5) cm 
ScanMax NS 
Med 
5 (+1) inches 
12.7 (+2.5) cm 
 
4.  Use the Detection Height setting to adjust the 
detection height for the checkout environment 
and to compensate for special mounting such 
as metal countertops. 
5.  Click the EXIT button on the configurator to 
exit the configurator. 
ScanMax IS Enhanced Detection Mode Option. To 
enable 16.5–17.8cm (6.5–7in) detection with 10.2–
12.7cm (4–5in) deactivation, set detection 
compensation on the diagnostics screen to +20 for X 
and Y. 
If only “one” ScanMax IS antenna is used it MUST be 
plugged into the Antenna 1 port or the unit will not 
function properly. 
If unexplained deactivation occurs… 
Follow this procedure (except step 3) for each 
antenna as autosync should be completed only 
once. Manual operation must be used thereafter, 
as autosync will take both antennas out of their 
previous sync delay settings. 
If false deactivation occurs, the configuration 
default values need to be modified as follows:  
1.  Plug your laptop programming cable into the 
POS 1/SERV port of the controller. 
2.  Start the AMB-9020 software configurator by 
clicking on the desktop icon. The Setup Screen 
appears (see Software Configurator Guide). 
3.  On the Setup screen, click the RESYNC 
button. Verify auto sync is enabled. If 
unexplained deactivation discontinues, 
readjust the Detection Height setting; 
otherwise, continue. 
4.  Ensuring no label/tag is close to the antenna, 
reduce the Detection Height setting one level 
at a time until the system does not false 
deactivate (firing without a label/tag present). 
Write this level down. 
5.  Set Detection Height level one step higher. 
Note: Maximum detection and deactivation 
height may be reduced compared with that 
listed in the table due to ambient noise and 
mounting locations. Note the new height. 
6.  If these steps fail to stop false deactivation, call 
the Customer Response Center for service.