Controller Status Indicators
Status Indicator on Controller (Note: Orange
lamp may appear yellow.)
lamp may appear yellow.)
Solid Green
Unit ready.
Blinking Green
Transmit disabled in detect
only mode or by key switch
or configurator.
only mode or by key switch
or configurator.
Blinking Orange
Controller is in auto-sync.
Solid Red
Non-recoverable fault.
Mode Indicator on Controller (Press the panel
button to cycle through the selections below.)
button to cycle through the selections below.)
SR LED on
The controller is set for use
with an SR label.
with an SR label.
SR LED off
The controller is set for use
with a DR label.
with a DR label.
MMS LED on
The controller is set for
Mag-Safe operation.
Mag-Safe operation.
MMS LED off
The controller is set for
routine operation.
routine operation.
MMS LEDs blinks
Antenna 1 EEPROM fault.
SR LED blinks
Antenna 2 EEPROM fault.
Status Indicators on
Remote Alarm Module (if used)
Remote Alarm Module (if used)
Green On, Red Off
Unit ready.
Blinking green
Transmit disabled in
detect only mode or by
key switch or
configurator.
detect only mode or by
key switch or
configurator.
Blinking green and red
(For PowerPad Pro,
blinking orange)
(For PowerPad Pro,
blinking orange)
Controller is in auto-sync.
Green on, Red flashing
every 250ms
every 250ms
The high voltage circuit is
not working.
not working.
One beep
The controller attempted
to deactivate a label.
to deactivate a label.
Slow beep until a hard tag
is removed from the field.
is removed from the field.
The controller is in HT
Test Mode.
Test Mode.
Multiple Fast Beeps
Label present in
Doublecheck or Detect
Mode.
Doublecheck or Detect
Mode.
Solid Red
Label present in Detect
Mode.
Mode.
Remote Alarm Module
The remote alarm module (Figure 2) plugs into the
REMOTE port on the controller. It contains the
following:
REMOTE port on the controller. It contains the
following:
a. Deactivation inhibit keyswitch. The key is
turned 90° to inhibit deactivation.
b. LEDs. Red and green LEDs indicate routine
operation, special modes, and system faults.
c. Beeper. Provides audio indication of detection.
d. High/Low volume control slide switch.
e. Phone jack. Receives a 2.1m (7ft) modular
cable from the REMOTE port on the controller.
f. Two keyhole slots (not shown). Two slots in
the back of the module attach it to a suitable
mounting surface. Two screws secure the unit.
mounting surface. Two screws secure the unit.
Note: You may need the remote alarm module to
diagnose certain problems with the deactivator.
diagnose certain problems with the deactivator.
Figure 2. Remote alarm module
b
f
c
e
d
a