Miscellaneous Functions
The following table contains miscellaneous functions not in other function groups.
“C” Function
Run 
Mode 
Edit
Defaults
Func.
Code
Name /
SRW Display
Description
–FEF 
(EU)
–FU 
(USA)
Units
C091 Debug mode enable
Displays debug parameters.
Two option codes:
00... Disable
01... Enable
00
00
DBG Slct     OFF
C101 Up/Down memory 
mode selection
Controls speed setpoint for the 
inverter after power cycle. Two 
option codes:
00... Clear last frequency 
(return to default frequency 
F001)
01... Keep last frequency 
adjusted by UP/DWN
00
00
UP/DWN    NO-STR
C102 Reset selection
Determines response to Reset 
input [RST].
Three option codes:
00... Cancel trip state at input 
signal ON transition, stops 
inverter if in Run Mode
01... Cancel trip state at signal 
OFF transition, stops inverter if 
in Run Mode
02... Cancel trip state at input 
signal ON transition, no effect 
if in Run Mode
00
00
RS Slct      ON