sequence of InstallatIons, fIGure 15a
Cut a length of PVC pipe about 3.5 inches (8.9 cm) longer than the 
wall thickness at the opening.  Glue the vent terminal to this section of 
pipe.  Slide the wall plate over the pipe to stop against the vent terminal.  
Place a bead of caulking (not supplied) around the gap between the 
pipe and cover plate.  Apply enough to fill some of the gap between 
the pipe and wall. Place some of the caulking on the back of the plate 
to hold it against the wall after installation.  If the vent pipe is installed 
up to the wall, with a coupling on the end against the wall opening, the 
pipe with the vent terminal can be prepared for gluing before inserting 
through the wall.  Slide the pipe through the wall and insert into the 
coupling on the other side of the wall, making sure that the vent terminal 
ends up pointed in the correct position, see Figure 15A.
vent terMInatIon - fIGure 15a
dIrect vent terMInal InstallatIon
The air intake provided on the unit contains a mesh screen to prevent 
large particles from entering the unit.
fIGure 15b
WHEN THE  UNIT  IS TO  BE  SETUP AS A  DIRECT  vENT, THE 
MESH SCREEN MUST BE REMOvED. THE INLET vENT PIPE 
MAY THEN  BE  GLUED TO THE AIR  INTAKE  (See  Figure  15B) 
PROvIDED ON THE UNIT.
THIS UNIT CONSISTS OF TWO vENT TERMINALS - AN INTAkE 
vENT TERMINAL AND AN EXHAUST vENT TERMINAL. THE INTAkE 
VENT TERMINAL IS A 2” 90° PVC ELBOW(-) WITH A MESH WIRE 
SCREEN AND THE EXHAUST VENT TERMINAL IS A 2” 22.5° PVC 
COUPLING WITH A MESH WIRE SCREEN.
NOTE:  TO  PREVENT  EXHAUSTING  PRODUCTS  FROM 
CIRCULATING  TO  THE AIR  INTAkE  IN  WINDY/COLD AREAS, 
THE MAXIMUM PRACTICAL DISTANCE BETWEEN THESE TWO 
TERMINALS IS RECOMMENDED.
fIGure 15c
InstallatIon sequence
vent terMInals supplIed wIth heater Must be used.
NOTE:  BEFORE  BEGINNING  INSTALLATION  OF  ANY 
VENT  PIPE  READ  THE  VENT  PIPE  MANUFACTURER’S 
INSTALLATION INSTRUCTIONS.
1.  After  the  points  of  termination  have  been  determined, 
use  the  cover  plates  as  templates  to  mark  the  holes  for 
the vent pipes to be inserted through the wall. BEWARE OF 
CONCEALED WIRING AND PIPING INSIDE OF WALL. If the 
vent terminals are being installed on the outside of a finished 
wall,  it  may  be  easier  to  mark  both  the  inside  and  outside 
wall. Align the holesby drilling a hole through the center of the 
template from the inside through to the outside. The template 
can now be positioned on the outside wall using the drilled holes 
as a centering point for the template.
    A.)  MASONRY  SIDE  WALLS  Chisel  an  opening  approximately 
   
1/2” (1.3 cm) larger than the marked circle.
    B.)  WOODEN SIDE WALLS Drill a pilot hole approximately 
     
one  quarter  inch  outside  of  the  marked  circle.  This 
     
pilot  hole  is  used  as  a  starting  point  for  a  saws-all  or 
     
sabre saw blade. Cut around the marked circle staying 
     
approximately  one  quarter  inch  outside  of  the  line. 
     
(This  will  allow  the  vent  pipe  to  easily  slide  through 
     
the  opening. The  resulting  gap  will  be  covered  by  the 
     
vent  terminal  cover  plates.)  Repeat  this  step  on  the 
     
inside wall if necessary.
2.  Cut a length of 3” PVC pipe about 3.5” (8.9 cm) longer than the 
  wall thickness at the opening.
3.  Glue the intake vent terminal to the section of the pipe.
4.  Slide the wall plate over pipe to stop against intake vent terminal.
5.  Place a bead of caulking (not supplied) around the gap between 
  the  pipe  and  the  wall.  Place  some  of  the  caulking  on  the 
  back of the plate to hold it against the wall after installation.
6.  If the vent pipe is installed up to the wall, with a coupling on the 
  end against the wall opening, the pipe with the vent terminal can 
  be prepared for gluing before inserting through the wall. Slide the 
  pipe through the wall and insert into coupling on the other side of 
  the wall, making sure that the vent terminal ends up pointed in the 
  correct position (Figure 15C and 16).
fIGure 16