4.  Parameters (User) 
4.1  Workpiece Coordinate 
 
 
 
I-140 
4.1.6  Workpiece position Measurement Function (M System) 
 
 
The workpiece position measurement function is used to measure each axis’ coordinate point by the sensor 
installed on the spindle contacting the workpiece with the manual feed or handle feed.  
 
The surface, hole center and width center coordinates are calculated from the measured coordinates, and 
those calculated results are set in the workpiece coordinate offset. 
 
Only 1st part system is available for the workpiece position measurement. 
 
 
(1)  Surface workpiece offset measurement procedure 
 
 
Perform an operation such as a 
reference point return to position the 
tool on the reference point.
1) 
 
 
 
Turn ON the measurement switch on 
the machine operation board. 
2) 
The message "  WLM  " appears. 
 
 
 
Move the sensor near the workpiece 
using manual feed and manual 
handle feed. 
3) 
 
 
 
Put the sensor in contact with the 
workpiece in the X-axis direction. 
4) 
Automatic re-contact movements are 
performed by the axis at the time of 
contact. 
The measurement coordinate value 
of the moved axis is displayed to the 
setting column. 
#(  )( 123.456 )(      )(      ) 
 
 
 
Set the setting number of workpiece 
coordinate system, then press the 
INPUT key. 
#( 54 )( 123.456 )(      )(      ) 
5) 
The value that subtracted external 
workpiece offset value from the 
measurement value is set to the 
X-axis specified workpiece coordinate 
system offset. 
The setting column will change to 
blanks. 
 
 
 
Carry out the operations in steps 3) 
to 5) in the same way for the Y-axis 
and Z-axis. 
6)