4.  Parameters (User) 
4.1  Workpiece Coordinate 
 
 
 
I-141 
 
 
Return the sensor to the reference 
point, and turn OFF the 
measurement switch. 
7) 
The message "  WLM  " disappears.
 
 
 
(2)  Hole center workpiece offset measurement procedure 
 
 
Perform an operation such as a 
reference point return to position the 
tool on the reference point.
1) 
 
 
 
Turn ON the measurement switch on 
the machine operation board. 
2) 
The message "  WLM  " appears. 
 
 
 
Move the sensor into the hole using 
manual feed and manual handle 
feed. 
3) 
 
 
 
Put the sensor in contact with the 
inner walls of the hole. 
Only one axis performs contact to 
the workpiece. 
4) 
Automatic re-contact movements are 
performed by the axis that did 
contact. 
The measurement coordinate value 
of the moved axis is displayed to the 
setting column. 
#(  )( 123.45 )(      )(      ) 
 
 
 
Set the contact position data 
(measurement coordinate)   
as point A. 
    #(      1)    INPUT 
5) 
The measurement coordinate value is 
set to point A (X, Y). 
The setting column is updated to #( 2).
The measurement A and data of 
movement axis are highlighted. 
The setting column will change to 
blanks. 
#1 TLM P. A 12.345 45.678